ACCESSORY USE (TS SERIES)
REMOTE CONTROL
RC2
RC2/90°
M
38.10
REV.0-12/11
PUSH AND
SCREW TIGHT
09/04/02 M38GB
PUSH AND
SCREW TIGHT
The remote control device for regulating the welding
current is connected to the front panel by means of
a multipole connector.
To regulate the current from the RC2, move the
switch (7), located above the multipole connector
(8), to "ON" position.
Position welding current adjusting (T) knob at the
necessary current value for the diameter and type
of electrode.