USE AS WELDER
MAGIC WELD 200 YD - YDE
M
34
REV.0-02/14
20/02/14 22270-GB
I
GB
F
It is prohibited for any unauthorized per-
sons to access areas adjacent to the en-
gine driven welder or the welding process.
ATTENTION
!
This symbol (Norm EN 60974-1 security
standards for arc welders) signifes that the
welders can be used in areas with increa-
sed risk of electrical shock.
ATTENTION
To reduce the risk of electromagnetic interfe-ren-
ce, keep the welding cable length short and keep
them on or near the ground. If possible, welding
operations should not be done near sensitive elec-
tronic devices. If interference continues to occur,
adopt additional measures: shift the group, use
shielded cables, line flters, shield the entire work
area.If the above solutions do not suffice,consult
our Technical Servicing Department.
!
ATTENTION
With a welding cable length up to 10 m is
suggested a section of 35 mm²; wìth longer cables
a bigger section is required.
!
CONNECT WELDING CABLES
Fully insert the welding cable
plugs into the corresponding
sockets turning them clockwise
to lock them in position.
Ensure that ground clamp,
whose cable must be connec-
ted to the (-) socket or the (+)
socket, according to the type of electrode, makes
good contact and that, if possible, it is close to the
welding position. Pay attention to the two polarities
of the welding circuit, which must not come into
electrical contact with each other.
PUSH AND
TWIST
ADJUSTING THE WELDING CURRENT
The
welding current is regulated
by turning knob “T” continuously. If
set to the minimum (turned fully in
an anticlockwise direction) it provi-
des a current of approximately 30
A; if set to the maximum (turned
fully in a clockwise direction) it
gives a maximum current of approximately 200A
(20V).
REMOTE CONTROL
The welding machine is predisposed for connection
to a remote control (optional) by means of the circu-
lar connector located on the front panel. Once the
connection to the remote control has been made,
the function of regulating the main potentiometer,
located on the front panel, will be automatically
switched to the remote control potentiometer.
PUSH AND
TWIST
The following table describes
the functions of each of the
connector’s contacts.
AUTO IDLE
Operation
When the engine is switched on it immediately
reaches a maximum speed of 3720 rpm for ap-
proximately 6/7 seconds for easy start up, after
which it automatically decreases and idles at 2650
rpm. It remains at this speed until current is drawn
when set to weld or auxiliary power.When set to weld
mode the machine reaches maximum engine speed
as soon as there is minimum contact between the
tip of the electrode and the piece to be welded and
also when set to generation drawing a minimum of
250 - 300 W.
The machine returns to minimum 6/7 seconds later
if power is not drawn during welding or generation.
CONTATTI DESCRIZIONE
A (
electric
ground
)
To the RC/TC potentiometer - GND
terminal
B
To the RC/TC potentiometer - V
CONTR
terminal
C
To the RC/TC potentiometer - V
REF
terminal
D
Remote connection presence contact -
wire bridge towards (C) cabling side
E
Non connected
F
G
H
I
J