‐ 34 ‐
to the power station.
During storage, please make sure to charge the power station
at least every six (6) months.
Keep all cooling holes open and clear of debris, mud, water, etc.
Cooling holes are located on the front panel and back panel of
the power station. If the cooling holes are blocked, the power
station may overheat and damage the battery, or inverter.
Store the unit in a clean, dry place. If possible, store the unit
indoors and cover it to give protection from dust and dirt.
7. PROTECTION
7.1 INPUT PROTECTION
Battery Charging Protection: When the battery is fully charged, the
charging input will automatically shut down, and
the all battery
segments in the LCD screen will stop blinking and remain solid.
Battery Low Voltage Protection: When the battery voltage is too
lower, the DC and AC output will automatically shut down. Fault
code 004 will show in the LCD screen, and the buzzer alarm will
sound. Charge the battery immediately.
Battery Over Voltage Protection: When the battery voltage is too
higher, the charging input will automatically shut down.
Fault code
008 will show in the LCD screen.
Stop charging the battery
immediately and contact an authorized dealer.