‐ 31 ‐ 

(3). Bind the bandages 1 around the battery 2.   
(4). Make sure the bandage 1 through the metal buckle 3 and pressed 
tightly by the metal buckle 3 as shown in the figure above. 
(5). The metal buckle 3 should be located on the side without 
waterproof joints as shown in the figure above. 

5.2.2 REINSTALL THE BATTERY INTO THE POWER STATION 

   

 

 

   

 

(1). Hold the battery 1 and put the battery 1 completely into the power 

2

4

5

Tighten

Summary of Contents for CP1000iL

Page 1: ...CPiL Series STATION POWER PORTABLE...

Page 2: ...tional 18 2 5 DC QUICK CHARGING INPUT optional 19 3 OPERATING THE POWER STATION 20 3 1 DC OPERATION 22 3 2 AC OPERATION 23 4 LCD DISPLAY 25 5 REPLACE THE BATTERY 28 5 1 REMOVE THE BATTERY 28 5 2 INSTA...

Page 3: ...hen the casing is open to prevent accidental electrical shock Electrical equipment including lines and plug connections should not be defective Do not connect to a building electrical system unless an...

Page 4: ...an authorized dealer Please DO NOT modify the unit in any way otherwise factory may reserve the right not to provide the complete warranty 1 UNIT DESCRIPTION 1 1 COMPONENTS IDENTIFICATION CP800iL CP10...

Page 5: ...and output receptacles 2 Charging Input Panel Location of power station charging input receptacles 3 Upper Cover Open the cover to connect install or replace the battery of the power station 4 Carryin...

Page 6: ...raw Bar Handle Pull the handle to wheel this power station around 6 Casing It is matched with the upper cover to form a closed casing of the power station 1 2 OUTPUT PANEL CP800iL CP1000iL 16 8 5 3 4...

Page 7: ...6 CP1500iL 11 1 2 13 14 9 10 12 14 2 4 1 13 7 6 8 5 16 15 3 11 9 10 12...

Page 8: ...7 CP2000iL CP2500iL CP3500iL 1 2 13 14 4 8 5 10 11 12 15 3 9 6 7 1 2 13 14 3 8 4 4 15 9 6 7 12 10 11 5 16 16...

Page 9: ...on hours or charging hours of the battery battery voltage total running time and fault warnings When the power station is charging the battery segments in the LCD screen will blink The power station i...

Page 10: ...oltage AC output is over voltage Over temperature in the inverter Battery is under voltage Battery is over voltage 15 Lighting The LED light bar can be used for lighting 16 Light Switch Press this swi...

Page 11: ...10 CP1500iL CP2000iL CP2500iL 4 2 1 5 3 6 5 3 2 1 4 7...

Page 12: ...ind Charging Input optional Charge the power station from wind turbines optional equipment 5 DC Quick Charging Input optional Charge the power station from DC 24V power unit optional equipment 6 Batte...

Page 13: ...e power station cannot be charged or used 3 As shown in the figure above put the battery connector 2 and power station connector 3 into the right position in the casing 4 and arrange all exposed conne...

Page 14: ...long term storage please charge the power station fully from AC charging for at least 10 hours to calibrate the battery capacity of the power station During storage please make sure to charge the powe...

Page 15: ...14 2 1 PV CHARGING INPUT Loosen 1 2 4 3 5 3...

Page 16: ...ort 2 to MC4 port 5 of solar panels 4 optional equipment by PV charging cable 3 which can be found in the packing box NOTE You can charge the power station quickly from several solar panels in series...

Page 17: ...other AC source by the AC charging cable 2 which can be found in the packing box NOTE The voltage of the AC charging CAN NOT exceed the AC INPUT voltage range Before using for the first time or after...

Page 18: ...er station from cars as follows Connect DC charging port 1 to cigarette lighter receptacle of 12V or 24V cars by DC charging cable 2 which can be found in the packing box NOTE The car engine must run...

Page 19: ...1 Remove the cover 1 from wind charging port 2 2 Connect wind charging port 2 to wind charging cable 4 of wind turbines optional equipment by wind charging plug 3 which can be found in the packing box...

Page 20: ...follows 1 Open the connector cap 1 on DC quick charging port 2 2 Connect DC quick charging port 2 to the DC plug 3 on the DC output cable 4 of DC 24V power unit optional to charge the power station N...

Page 21: ...20 DO NOT short circuit the DC quick charging port 2 3 OPERATING THE POWER STATION CP800iL CP1000iL 16 8 5 3 4 11 1 2 13 14 9 10 12 6 7 15...

Page 22: ...21 CP1500iL CP2000iL CP2500iL 14 2 4 1 13 7 6 8 5 1 2 13 14 4 8 5 10 11 12 15 3 9 6 7 16 15 3 11 9 10 12 16...

Page 23: ...of 12V DC electric devices to choose suitable one to connect 3 Receptacle 5 6 and 7 all are DC output ports for USB or Type C plugs The maximum output power of the Type C 6 is 60W and the maximum out...

Page 24: ...to the connected appliance s will shut off 3 2 AC OPERATION You can use the AC output from the power station as follows 1 Push the main switch 3 to ON position 2 Push the AC switch 1 to ON position 3...

Page 25: ...condition before connection to the power station Be sure the total AC load is within the power station rated output The rated and maximum output power of the power station is based on resistive load...

Page 26: ...e AC output to the connected appliance s will shut off 4 LCD DISPLAY You can activate the display backlight by pressing any of the three buttons S The built in LCD Display can indicate some important...

Page 27: ...hat your appliances are using while plugged into the power station Shows the value in Ah for remaining capacity of the battery by pressing the button once and for total running time in HOURS by pressi...

Page 28: ...t is overloaded or short circuited Check DC appliances cables plugs and reduce power of appliances Fault code 004 means that the battery voltage is too lower Charge the battery immediately Fault code...

Page 29: ...miliar with maintenance work have an authorized dealer do it for you Use ours or equivalent specifications dimensions quality batteries for replacement Ask an authorized dealer for further attention T...

Page 30: ...29 1 3 6 8 8 5 4 7 3 Unscrew...

Page 31: ...hen remove gasket 6 and remove battery baffle 7 Two kinds of the spanner 4 can be found in the packing box 4 Hold the battery bandage 8 and remove the battery from the power station 5 2 INSTALL THE BA...

Page 32: ...ssed tightly by the metal buckle 3 as shown in the figure above 5 The metal buckle 3 should be located on the side without waterproof joints as shown in the figure above 5 2 2 REINSTALL THE BATTERY IN...

Page 33: ...he gasket 3 Note that the feet on the gasket 3 should be placed in the positioning slot as shown in the figure above 3 Tighten screw 5 with the spanner 4 Two kinds of the spanner 4 can be found in the...

Page 34: ...then press the upper cover 1 tighten all buckle 2 and finally tighten the two screws 3 NOTE Before using for the first time please charge the power station fully from AC charging for at least 10 hour...

Page 35: ...OTECTION 7 1 INPUT PROTECTION Battery Charging Protection When the battery is fully charged the charging input will automatically shut down and the all battery segments in the LCD screen will stop bli...

Page 36: ...rcuited problems Inverter Over Temperature Protection When the temperature in the inverter is too higher AC output will automatically shut down The buzzer alarm will sound 5 times uninterruptedly and...

Page 37: ...ion cords and all items being powered then push the main switch to reset module Reduce loads and push the main switch to reset module NO NO Turn off the electrical appliance connected to the power sta...

Page 38: ...ion YES NO Does the over temperature indicator on the screen panel or APP go on Turn off the electrical appliance connected to the power station and put the power station in a cool place to cool it th...

Page 39: ...Reduce loads and push the AC switch to reset module YES Is the AC output overloaded The warning light on the panel flashes Check and correct condition of any extension cords and all items being powere...

Page 40: ...m 575 421 287mm 575 421 287mm 575 421 387mm Weight 17kg 16kg 26kg 37kg 42kg 55kg Battery Type LiFePO4 Battery Capacity 858Wh 67Ah 12 8V 691Wh 27Ah 25 6V 1715Wh 67Ah 25 6V 2048Wh 80Ah 25 6V 2688Wh 105A...

Page 41: ...00W 3 hours fully charged 12 15V 24 30V Max 160W 15 hours fully charged 36 140V Max 600W 3 hours fully charged 100 120V 200 240V Max 300W 7 hours fully charged CP1500iL 24 28V Max 2000W 1 5 hours full...

Page 42: ...capacitive load shall be small enough compared with the rated power of the power station and the ratio of the two shall not exceed the power factor of the load otherwise the power station may be over...