The chimney and the flue pipe must be fitted with cleaning doors, which must be at least
the same size as the chimney’s aperture area.
The chimney must be accessible for external inspection, and it must be possible to access
the cleaning doors and the chimney if it is to be cleaned from the top (e.g. steel chimneys).
1.6 Connecting to a brick chimney
A flue-duct liner is bricked into the brick chimney, and
the supplied strap is taped onto the flue duct about 12
cm from the edge of the duct. The duct must not be
inserted into the actual chimney opening, as you can
go no further than to the interior side of the chimney
embrasure. Ordinarily it will not be necessary to seal
off pipe joints, if any.
If the flue pipe transitions from horizontal to verti-
cal, it is a good idea to install it with a gentle bend so
as to avoid any loss of draught.
The flue pipe must be dimensioned in accordance
with national and local regulations. Morsø recom-
mends, however, that flue pipes be made of 2 mm
sheet steel as this will extend the service life.
1.7 Connecting to a steel chimney
If your installation involves taking the chimney straight up and through the ceiling, you must com-
ply with National, Local Building Regulations or flue manufacturers instructions concerning clear-
ances to combustible materials such as walls, floor joists and ceilings. The joint between the stove
flue collar and the stovepipe must also be sealed using glass fibre rope. It is important that the
insulated flue system is properly supported both at ceiling level and at roof level.
THE STOVE MUST NOT BEAR THE WEIGHT OF THE CHIMNEY SYSTEM (See chimney man-
ufacturer’s instructions). Excessive weight on the stove will inhibit expansion and could lead
to damage of the stove top. Damage caused to the stove in this way would not be covered by
the manufacturers guarantee.
If a chimney fire should occur as a result of incorrect operation of the stove or prolonged
use of wet fuel, close the vents completely and contact the fire brigade.
Be aware of the following:
Cleaning procedure: Discuss this with chimney sweep or qualified installer prior
to or during the stove installation
If there is insufficient draught in the chimney, it may be a good idea to install the
flue pipe straight up so as to minimise smoke migration in the actual combustion
chamber.
Avoid having any more than 2 bends in the flue system and limit the length of the
offset between bends.
Fresh air supply
A wood-burning stove requires air for combustion. As a result, firing a wood-burn
B
B
SECTION
B-B
SCALE
1 : 12
3
2
1
C
C
SECTION
C-C
SCALE
1 : 12
1
2
3
300**
150
300
400*
Zone: Rev.:
Description
Date
Sign.:
Revisions
Title:
Drawing no.:
1:50
Til vejledning
Morsø 5660M
RSV
04.12.2017
A2
Date of print: 02-03-2018
U:\udv\Tegninger\5600\5600 Assembly.SLDASM
5600-184 a
Itemno.:
This drawing is Morsø Jernstøberi A/S' property and must not be sold, lended or copied without any written authorization from the company.
Material:
Weight kg.:
Model no.
Drawingtype:
Location of file:
Scale:
Format:
Released:
Construction: