4
The hearth
The hearth
The hearth
The hearth
The hearth must be made from a non-combustible material and be at least
600mm wide x 500mm deep x 12mm thick
Clearances
Clearances
Clearances
Clearances
Clearances from combustible and non-combustible materials must be at
least those shown in figure 1
The flue
The flue
The flue
The flue
The flue may be:
(a)
A conventional open flue.
(b)
A metallic gas flue pipe a diameter of 125 mm. The
connection collar is for 150 mm dia. flue pipe. The
flue installation dimensions are shown in figure 1.
•
No restrictor plate or flue damper is permitted. Where a variable damper
is fitted it must be removed or be permanently fixed in the open position.
•
The flue must be swept before the appliance is installed.
V
V
V
V
Ventilation:
entilation:
entilation:
entilation:
entilation: In the United Kingdom (GB) no special ventilation bricks or vents
are required in the room for this appliance.
In the Republic of Ireland (I.E.), permanent ventilation must comply with the
regulations currently in force.
Location:
Location:
Location:
Location:
Location: This appliance must not be installed in a private garage or any
room, which contains a bath, or shower or where steam is regularly present.