Morso 553 Installation Instructions Manual Download Page 2

2

As supplied, this stove is for use with natural gas (G20)
When converted using conversion kit no. 555311 this appliance is for
use with propane gas (G31)
This appliance is for use in the United Kingdom (GB) and the Republic
of Ireland (IE) only.

LIST OF COMPONENTS

LIST OF COMPONENTS

LIST OF COMPONENTS

LIST OF COMPONENTS

LIST OF COMPONENTS

Cast iron stove containing  gas burner unit & interior flueway
1 Door handle with fixing screw
1 Ceramic rear base piece
1 Pair of ceramic front base pieces
1 Set of 3 top coals
1 Pair of ceramic firebox side walls
1 8mm nut & olive
1 Key for window
1 Set of Installation and user’s instructions
1 Flue sealing rope

APPLIANCE DA

APPLIANCE DA

APPLIANCE DA

APPLIANCE DA

APPLIANCE DAT

T

T

T

TA

A

A

A

A

This product uses fuel effect pieces, firebox side walls and gaskets containing
Refractory Ceramic Fibres (RCF), which are man-made vitreous silicate fibres.
Excessive exposure to these materials may cause temporary irritation to eyes,
skin and respiratory tract. Consequently, it makes sense to take care when
handling these articles to ensure that the release of dust is kept to a minimum.
To ensure that the release of fibres from these RCF articles is kept to a minimum,
during installation and servicing we recommend that you use a HEPA filtered
vacuum to remove any dust and soot accumulated in and around the stove
before and after working on the stove. When replacing these articles we
recommend that the replaced items are not broken up, but are sealed within
a heavy duty polythene bag, clearly labelled as RCF waste. This is not classified
as “hazardous waste” and may be disposed of at a tipping site licensed for
the disposal of industrial waste. Protective clothing is not required when
handling these articles, but we recommend you follow the normal hygiene
rules of not smoking, eating or drinking in the work area and always wash
your hands before eating or drinking.
This appliance does not contain any component manufactured from asbestos
or asbestos related products.

Summary of Contents for 553

Page 1: ...f the type of gas and pr identification of the type of gas and pr identification of the type of gas and pr identification of the type of gas and pr identification of the type of gas and pressur essur essur essur essure e e e e and the adjustment of the appliance ar and the adjustment of the appliance ar and the adjustment of the appliance ar and the adjustment of the appliance ar and the adjustmen...

Page 2: ...re to these materials may cause temporary irritation to eyes skin and respiratory tract Consequently it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum To ensure that the release of fibres from these RCF articles is kept to a minimum during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust an...

Page 3: ...ces are installed by competent persons in accordance with the current edition of the Gas Safety Installation and Use Regulations Failure to install the appliance correctly could lead to prosecution The Council for the Registration of Gas Installers CORGI requires its members to work to recognised standards In the United Kingdom the installation must also be in accordance with a All the relevant pa...

Page 4: ...n figure 1 No restrictor plate or flue damper is permitted Where a variable damper is fitted it must be removed or be permanently fixed in the open position The flue must be swept before the appliance is installed V V V V Ventilation entilation entilation entilation entilation In the United Kingdom GB no special ventilation bricks or vents are required in the room for this appliance In the Republi...

Page 5: ...rovided for an 8mm pipe inlet connection to the elbow at the bottom front of the appliance The elbow can be rotated to allow a connection from any direction The elbow includes a valve for isolating the gas supply The supply pipe must be rigid material Flexible pipe must not be used Note Prior to connecting the gas supply it is advisable to blow out the gas supply so that any dirt which may be pres...

Page 6: ... 6 6 The double top coals are marked L and R Place the coal marked L behind the front left coal Place the coal marked R behind the front right coal Place the single coal between the two double coals See figure 7 7 Close and secure the windows by refitting the locking screw Figur Figur Figur Figur Figure 2 e 2 e 2 e 2 e 2 Figur Figur Figur Figur Figure 3 e 3 e 3 e 3 e 3 Figur Figur Figur Figur Figu...

Page 7: ...ld light the pilot If the pilot does not ignite keep the knob depressed for a few seconds to purge air from the supply pipes Then turn back to the off position marked and repeat the ignition procedure When the pilot has lit keep the right hand control knob depressed for a few seconds to allow the pilot flame to stabilise then release it If the pilot does not remain alight ensure that the air has b...

Page 8: ...cated at the side of the control unit See figure 9 The pressure check should be carried out using a calibrated pressure gauge after removing the test point screw The fire should be alight and the left hand control knob at its fully anticlockwise setting Maximum flame height The pressure setting should be within the limits shown on page 3 of this manual Appliance data After checking the pressure tu...

Page 9: ... the appliance and disconnect it Advise the customer of the pr the appliance and disconnect it Advise the customer of the pr the appliance and disconnect it Advise the customer of the problem oblem oblem oblem oblem and str and str and str and str and stress that the appliance must not be used until the pr ess that the appliance must not be used until the pr ess that the appliance must not be used...

Page 10: ...lied with the appliance and that any r supplied with the appliance and that any r supplied with the appliance and that any r supplied with the appliance and that any replacements must only eplacements must only eplacements must only eplacements must only eplacements must only be the authorised spar be the authorised spar be the authorised spar be the authorised spar be the authorised spares W es W...

Page 11: ...early labelled as RCF waste This is heavy duty polythene bag clearly labelled as RCF waste This is heavy duty polythene bag clearly labelled as RCF waste This is not clasified as hazardous waste and may be disposed of at a not clasified as hazardous waste and may be disposed of at a not clasified as hazardous waste and may be disposed of at a not clasified as hazardous waste and may be disposed of...

Page 12: ...12 72146400 morsø bogtrykkeri 97 72 10 44 ...