CHIMNEY REQUIREMENTS

 

 

 

For proper draft and best performance, the chimney should extend at least 15’ (4.6m) and not more 
than 35’ (10.6m) above the level of the MORSØ Model 5660 STANDARD or Model 5660NA hearth. 
The chimney must be properly installed and supported in accordance with the chimney manufac- 
turer’s instructions. The enclosure is not intended to support the entire weight of the chimney.  Sup- 
port components are available from the chimney manufacturer. 

 

If possible, an installation with a straight vertical chimney will provide the best draft and will be easi- 
est to clean. 

 

If a straight chimney is not possible due to obstructions, up to four 30° elbows may be used to offset 
the chimney around the obstructions.  The elbows must be used in pairs in order to return the chim- 
ney to vertical after passing the obstruction.  The first offset must be at least 8’ (2.5m) above the 
Insert hearth. 

 

The 

Morsø 

Fireplace Insert Enclosures are approved for installation in the united States with the 

following chimneys: 

 

Metal Fab, Inc. 

Model TG 

Security Chimneys 

Model ASHT 

Selkirk Metalbest 

Model Ultra-Temp 

Simpson-Dura-Vent 

Model Dura-Plus (SDP) 

 

 
 

The chimney installation begins with a base plate or anchor plate mounted to the top of the Fireplace 
Insert Enclosure.  Before the base plate is installed on the enclosure top, the flexible stainless steel 
flue connector (provided with the enclosure) that will connect the Insert to the chimney system must 
be attached to the base plate using the four provided sheet metal fasteners.  See FIG. 1.  Next, in- 
sert the anchor plate/flex connector assembly down through 
the hole in the top of the enclosure.  Use the four provided 
sheet metal fasteners to secure the base/anchor plate to 
the enclosure top. 

 

Next slide the stainless steel 45° slip connector elbow all 
the way onto the stainless flex connector in preparation for 
installing the Insert. 

Chimney Base/ 
Anchor Plate 

 

 
 
Sheet Metal 
Fasteners 

 
 
 

Stainless Steel 
Flex Connector 

 
 

 

 

 
 

FIG. 1 

Stainless Steel 
45° Slip Elbow 

 

Summary of Contents for 90566000

Page 1: ...RT MODEL 5660 STANDARD Mors US LLC 1011 Hwy 52 West Portland TN 37148 TEL 615 323 0561 Report 192 S 22 2 192 S 22b 2 INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for futu...

Page 2: ...LED IN THESE FIREPLACE INSERT ENCLOSURES IN THE UNITED STATES THE MORS MODELS 5660 STANDARD AND 5660NA FIREPLACE INSERTS MUST ONLY BE CONNECTED TO ONE OF THE SPECIFIC CHIMNEYS LISTED ON PAGE 4 OF THIS...

Page 3: ...or Model 90566400 Fireplace Insert Enclosure may be elevated off the floor to allow the Insert Model 5660 STANDARD or 5660NA to be placed higher up on the wall This will require construction of a base...

Page 4: ...e Insert hearth The Mors Fireplace Insert Enclosures are approved for installation in the united States with the following chimneys Metal Fab Inc Model TG Security Chimneys Model ASHT Selkirk Metalbes...

Page 5: ...est that the framing for the area directly above the standoff on the MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS A 10 254mm front of the enclosure be done after the enclosure is secured in place and ch...

Page 6: ...utside air duct to pass through the rear wall of the Fireplace Insert Enclo sure VENTILATION AIR The chase or cavity in which the enclosure is installed must be ventilated with air from outside of the...

Page 7: ...MENDED ROUGH FRAMING DIMENSIONS C B A FIG 2 Framing Front View FIG 3 Framing Side View A 67 1702mm B B 39 3 4 1010mm C C 25 1 2 648mm Minimum Note These dimension are for both Model 90566000 and Model...

Page 8: ...MINIMUM CLEARANCES TO ADJACENT COMBUSTIBLE MATERIALS Combustible Non Combustible Material Limits E 39 3 4 1010mm F 67 1702mm G 28 3 4 730mm J 29 1 4 742mm Ceiling E D D 67 1702mm Minimum Non Combustib...

Page 9: ...ombustible materials may be used if there are no gaps or joints between pieces that would allow coals or embers to reach the combustible floor underneath Floor protectors meeting the requirements of U...

Page 10: ...ish material may be applied over non combustible tile backer board The requirements for the facing material applied inside the combustible limits are The material must be non combustible The total thi...

Page 11: ...Install the Insert into the Fireplace Insert Enclosure 1 Using a helper or stove lifter place the insert on the platform inside the enclosure Push the in sert back into the enclosure opening until the...

Page 12: ...12...

Page 13: ......