background image

 

Installing the Insert into the Enclosure 

 

 

Prepare the Insert

 

Refer to the Morsø Installation and Operating Instructions for either Model 5660 NA Standard or 
5669 NA  with New Blower for instructions on how to prepare the insert for installation. 

 

Follow the Blower Installation instructions on page 14 if you are installing the Insert  with the optional 
blower.  Plug the blower power cord into the electrical outlet in the side of the enclosure.  Route the 
power cord between the insert stand and the enclosure side. 

 

In order to connect the chimney to the insert it is necessary to remove the baffle and firebox liners. 
It is not necessary to completely disassemble the insert.  Do not remove the cast iron flue collar. 
The instructions in the Morsø Insert manual will show you how to do this starting on page 6. 

 

Install the Insert into the Fireplace Insert Enclosure

 

1.  Using a helper or stove lifter, place the insert on the platform inside the enclosure.  Push the in- 

sert back into the enclosure opening until the insert flange contacts the facing material.  Check to 
be sure the insert is centered in the enclosure opening. 

2.  Adjust the leveling screws until the face plate is level and plumb or aligned with any joints in the 

facing material. 

3.  Reach up through the flue opening and pull down on the stainless steel 45° slip connector elbow 

using the handle provided in the elbow.  Make sure the connector elbow is full engaged in the 
insert flue flange.  See FIG. 11. 

4.  Bend the two tabs over to secure the connector elbow. See FIG. 12. 
5.  Replace the baffle using the reverse order for removal. 
6.  Replace the stones (firebrick). 
7.  Replace the  door 

 
 
 
 
 

 

Chimney Base/ 
Anchor Plate 

 
 
 

 

Stainless Steel 
Flex Connector 

 

Stainless Steel 
45° Slip Elbow 

 

 

Flue Flange 

 

 

FIG.11 Cutaway View Showing Flue Connection 

 
 
 
 
 

 

11 

 

 
 

 

 

 

FIG.12 Bending Flue Tabs 

 
 
 
 
 
 
 
 
 

V1.US 

Summary of Contents for 90566000

Page 1: ...RT MODEL 5660 STANDARD Mors US LLC 1011 Hwy 52 West Portland TN 37148 TEL 615 323 0561 Report 192 S 22 2 192 S 22b 2 INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for futu...

Page 2: ...LED IN THESE FIREPLACE INSERT ENCLOSURES IN THE UNITED STATES THE MORS MODELS 5660 STANDARD AND 5660NA FIREPLACE INSERTS MUST ONLY BE CONNECTED TO ONE OF THE SPECIFIC CHIMNEYS LISTED ON PAGE 4 OF THIS...

Page 3: ...or Model 90566400 Fireplace Insert Enclosure may be elevated off the floor to allow the Insert Model 5660 STANDARD or 5660NA to be placed higher up on the wall This will require construction of a base...

Page 4: ...e Insert hearth The Mors Fireplace Insert Enclosures are approved for installation in the united States with the following chimneys Metal Fab Inc Model TG Security Chimneys Model ASHT Selkirk Metalbes...

Page 5: ...est that the framing for the area directly above the standoff on the MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS A 10 254mm front of the enclosure be done after the enclosure is secured in place and ch...

Page 6: ...utside air duct to pass through the rear wall of the Fireplace Insert Enclo sure VENTILATION AIR The chase or cavity in which the enclosure is installed must be ventilated with air from outside of the...

Page 7: ...MENDED ROUGH FRAMING DIMENSIONS C B A FIG 2 Framing Front View FIG 3 Framing Side View A 67 1702mm B B 39 3 4 1010mm C C 25 1 2 648mm Minimum Note These dimension are for both Model 90566000 and Model...

Page 8: ...MINIMUM CLEARANCES TO ADJACENT COMBUSTIBLE MATERIALS Combustible Non Combustible Material Limits E 39 3 4 1010mm F 67 1702mm G 28 3 4 730mm J 29 1 4 742mm Ceiling E D D 67 1702mm Minimum Non Combustib...

Page 9: ...ombustible materials may be used if there are no gaps or joints between pieces that would allow coals or embers to reach the combustible floor underneath Floor protectors meeting the requirements of U...

Page 10: ...ish material may be applied over non combustible tile backer board The requirements for the facing material applied inside the combustible limits are The material must be non combustible The total thi...

Page 11: ...Install the Insert into the Fireplace Insert Enclosure 1 Using a helper or stove lifter place the insert on the platform inside the enclosure Push the in sert back into the enclosure opening until the...

Page 12: ...12...

Page 13: ......