6.0 TECHNICAL SPECIFICATIONS

15

M

ECHANICAL

• Dimensions: (inches) ........... 6.01 (W) x 4.14 (H) x 2.17 (D)

(mm) ............... 153 (W) x 105 (H) x 55 (D)

• Weight:

(oz) ................. 12

(kg) ................. 0.34

• Wire terminals ..................... Euro-style

Max wire size:

(solid) .............. #6 AWG/16 mm

2

(multistrand) ... #6 AWG/10 mm

2

(fine strand) .... #8 AWG/10 mm

2

Terminal diameter ........... 0.2 inch/5 mm

• Mounting orientation ......... vertical

• Case:

Material

........................ VALOX #310 SEO

Fungicidal resistance ....... ASTM G21-70

Moisture absorption ........ < 0.4%

UL Thermal Index ............ 120

°

C/140

°

C

E

LECTRONIC

 F

USE

 / S

YSTEM

 S

AFETY

• Load short-circuit ................ Short-circuit is > 10X load

rating for > 5 msec

........................ Load disconnected < 50

microsec

• Emergency disconnect ....... If voltage < 2.4 V, PV/load

disconnected < 0.1 sec

• Reverse polarity .................. All 4 system inputs fully

protected

• High temp shutdown .......... 70

°

C disconnect PV input

80

°

C disconnect load

60

°

C reconnect load

50

°

C reconnect PV

C

ONTROL

 S

ETPOINTS

12 Volt

Sealed

Flooded

• Low volt load disconnect

11.4

11.5

• LVD reconnect

12.5

12.6

• Constant-voltage regulation 14.1

14.3

• Equalization

14.35

14.6

• HVD

15.5

15.5

(24V setpoints are twice 12V values)

C

ONTROL

 P

ARAMETERS

• Charge algorithm ............... constant-voltage

PWM pulse charging

series configuration

• Temp comp coefficient ...... - 5.0 mV/

°

C/cell (25

°

C ref)

• LVD current coefficient ....... - 20 mV/amp load

• Auto equalize:

Sealed

........................ 16 days or 11.9/23.8 V

Flooded

........................ 11 days or 12.0/24.0 V

• Temp comp setpoints ........ Regulation, Equalize, HVD

• Software delays .................. LVD = 55 sec; HVD = 7 sec

• Software filtering ................ average 2 inputs/50 

µ

sec

• Measurement rate .............. 37.5 samples/sec

Specifications subject to change without notice.

R

ELIABILITY

5-year failure rates at a 90% confidence level

• ProStar-12 .................................... < 0.1%

• ProStar-20 .................................... < 0.1%

• ProStar-30 ....................................     0.4%

E

NVIRONMENTAL

• Operating temperature ................ -40 to +85

°

C

• Max ambient temperature ........... +60

°

C

• Storage temperature .................... -55 to +100

°

C

• Humidity ....................................... 100% (NC)

P

ERFORMANCE

 / E

LECTRICAL

• Accuracy

12V ........................... +/- 22 mV

24V ........................... +/- 38 mV

• Maximum array voltage ................ 50 V

• Min voltage to operate ................ 8.0 V

• Ground

................................. negative

• Parallel capability ......................... yes

• Self-consumption (tare):

Night

................................. 11 mA

Charging ................................. 12 mA

Load disconnected ................... 10 mA

• Voltage drops:

Maximum: PV/Batt ..................... 0.7 V

Batt/Load ................. 0.4 V

Typical:

PV/Batt ..................... 0.5 V

Batt/Load ................. 0.1 V

• Operating life ............................... 15 years

• Noise:

µ

P protection ........................... all inputs

Output noise pulses ................. < 400 mV

Noise pulse width .................... < 500 nanosec

Radiated noise ......................... < 100 picowatts/Khz

• FET’s:

Rds (on resistance) ................... 0.018 ohm

Pulse rating .............................. 120 A

Junction temp rating ................ 175

°

C

Operating junction temp ......... 110

°

C

• 

µ

P memory ................................. 2k ROM

• 

µ

P clock speed ............................. 2 Mhz

• Transient surge suppressors:

Pulse power rating ................... 1500 watts

Response ................................. < 5 nanosec

• LED’s:

Pulse rate ................................. 300 Hz

Current consumption ............... < 1 mA/LED

M

ETER

 D

ISPLAY

• Type ............................................. LCD

• Display .......................................... 3-digit x .5 inch

• Temp rating .................................. -30 to +85

°

C

• Voltage accuracy .......................... 0.5%

• Current accuracy .......................... 2.5%

• Status LED’s ................................. 3

• Self-consumption (tare) ................ 8.5 mA

• Manual disconnect ....................... < 100 microsec

M

ODEL

 R

ATINGS

ProStar-12

ProStar-20

ProStar-30

PV current (amps)

12

20

30

Load current (amps)

 8

16

30

Note: Current ratings can be exceeded by 25% for up to 5 minutes.

• All models both 12V

and 24V (automatic
selection)

Manufactured in the U.S.A.

Summary of Contents for PROSTAR-12

Page 1: ...R S OPERATOR S MANUAL PRO ROSTAR TAR MODEL RATINGS PROSTAR 12 PROSTAR 20 PROSTAR 30 Rated PV current 12A 20A 30A Rated Load current 8A 16A 30A System voltage 12 and 24 volts auto selected ProStar mod...

Page 2: ...s a highly sophisticated controller using advanced technology and microprocessor control The battery charg ing process has been optimized for longer battery life and improved system performance Many f...

Page 3: ...lots Do not short circuit the PV array while connected to the controller This will damage the controller Do not exceed the current ratings of the controller 2 0 QUICK START INSTRUCTIONS This section p...

Page 4: ...is disconnected 8 The ProStar will automatically select for a 12 or 24 volt sys tem If this is a 24 volt system first check to confirm that the battery is above 17 volts and boost charge the battery i...

Page 5: ...nt and load current The meter will automatically sequence between these 3 parameters The 3 small green status LED s will indicate which parameter is being displayed The LCD meter will operate from 30...

Page 6: ...state Battery Reversed No LED s will light No damage will occur Sense Correct No additional indications Sense Reversed If the battery has been connected cor rectly there will be sparking at the termi...

Page 7: ...be made in any order However the BATTERY must be connected first for the LED indicators to operate The SENSE input will not power the LED s INSTALLATION STEPS 1 Inspect the controller for shipping da...

Page 8: ...ck the battery polarity The green yellow or red BATTERY CHARGE LED will light depending on the battery charge state 4 SENSE and Battery sense leads are recommended if the controller is located more th...

Page 9: ...ng setpoints from a sealed to a flooded battery When the change has been made the green BATTERY TYPE LED will turn off Check the LED to confirm the change This SELECT PIN can be used repeatedly No dam...

Page 10: ...FUNCTIONS The PV system operator should become familiar with the following functions of the ProStar controller Refer to Technical Specifications 6 0 for actual setpoints and other parameter values LV...

Page 11: ...e or elapsed time NOTE Actual charging setpoints of the ProStar controller are adjusted for temperature equalizations and bat tery type In addition many delays are built into the controller Remember t...

Page 12: ...nternal fuses or circuit breakers in the ProStar case There is nothing inside the case that can be adjusted and there are no consummable parts to replace 1 BATTERY IS NOT CHARGING a Check for proper L...

Page 13: ...controller s microprocessor should be reset restarted if any of the following conditions seem to exist The microprocessor latches locks up The controller seems to be operating at the wrong system volt...

Page 14: ...ion 4 2 6 e If the ProStar internal temperature is above 80 C the load will be disconnected All LED s will be flashing in sequence Check to ensure for clear airflow around the ProStar and that nothing...

Page 15: ...Software filtering average 2 inputs 50 sec Measurement rate 37 5 samples sec Specifications subject to change without notice RELIABILITY 5 year failure rates at a 90 confidence level ProStar 12 0 1 P...