Morita Lubrina HIM-1 Operation Instructions Manual Download Page 10

Operation  2018-05-21 

8

 

3.

 

Parts Identification 

 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Power Cord Connection 

Fuse Holder 

Front Door 

Operation Panel 

Side Door 

Tray Filter 

Tray

Selector Switches 

Selector Lamps (green) 

Power Lamp (green) 

Spray Can Empty Lamps (orange) 

Finished Lamp (green) 

Start, Stop and Set Switch 

Rating Label 

Main Switch 

Air Regulator 

Summary of Contents for Lubrina HIM-1

Page 1: ...handpiece maintenance unit The Lubrina lubricates and internally cleans dental handpieces easily and effectively For optimum safety and performance read this manual thoroughly before using the unit a...

Page 2: ......

Page 3: ...NTION 3 1 Warning and Prohibitions 4 2 Technical Specifications 5 3 Parts Identification 8 4 Set Up 11 5 Operation 16 6 Maintenance and Replacement Parts 25 7 Maintenance and Inspection 30 8 Troublesh...

Page 4: ...lity of danger and operating the unit in accordance with the manufacturer s recommendations First thoroughly read all precautions and instructions pertaining to safety and accident prevention then ope...

Page 5: ...he instrument in ways other than the operating procedures described in this manual or resulting from the safety precautions and warnings in this manual not being observed 6 Workplace conditions and en...

Page 6: ...t themselves The Lubrina cannot be used for air bearing handpieces Astron series Electromagnetic wave interference caused by cellular phones transceivers remote controls and similar transmission devic...

Page 7: ...pprox 10 kg Size including regulator Width 300 mm Height 370 mm Depth 300 mm Product Description Used to maintain optimum performance and prolong working life of dental handpieces Delivers oil and air...

Page 8: ...be recycled Metal parts of the equipment are disposed as scrap metal Synthetic materials electrical components and printed circuit boards are disposed as electrical scrap Material must be disposed acc...

Page 9: ...n Device CAUTION Federal law restricts this device to sale by or on the order of a dentist U S A cTUVus certification mark U S A and Canada CE marking Conforms with the European Directive 93 42 EEC an...

Page 10: ...Cord Connection Fuse Holder Front Door Operation Panel Side Door Tray Filter Tray Selector Switches Selector Lamps green Power Lamp green Spray Can Empty Lamps orange Finished Lamp green Start Stop an...

Page 11: ...Operation 2017 12 27 9 Connection Nut Chuck Nozzle Nozzle Guide Oil Case Oil Pad...

Page 12: ...bsorption Case 1 Power Cord 1 CODE No 6812612 CODE No 6812631 CODE No 6812650 CE 230 V CODE No 6812657 120 V Tray Filter 1 Tray 1 Spray Can Stand 2 for Europe only CODE No 6812614 CODE No 6812632 CODE...

Page 13: ...en space around the unit 1 Air Connection 1 Connect the green air tube provided to the air regulator and the main air supply Open the valve for the main air supply The main air supply must be clean an...

Page 14: ...so that the equipment can be cut off from the supply mains when necessary Do not place this equipment where the main switch cannot be operated 3 Coupling Fit the coupling onto the nozzle and tighten...

Page 15: ...place Slide the tray all the way in otherwise a film of oil will be deposited on the unit 6 Spray Cans 1 Open the side door Press the spot indicated in the photo to open the door 2 Set the stands for...

Page 16: ...ers down to a horizontal position to secure the cans Oil will leak or spray out if the cans are not properly installed Make sure the lock levers are all the way down Otherwise the oil will not come ou...

Page 17: ...Operation 2006 02 21 15 7 Spray Can Removal 1 Pull the lock lever straight up to lower the stand 2 Take the can out If the can s nozzle is stuck in place simply pull it down slightly and take it out...

Page 18: ...pe the handpiece with gauze dampened with Ethanol for Disinfection Ethanol 70 vol to 80 vol Lubrina Procedure Clean and Lubricate Perform chuck maintenance for Morita ball bearing handpieces Perform t...

Page 19: ...d fire during an electrical storm Turn the Lubrina off and disconnect its cord from the power outlet Wear surgical gloves to operate and clean the Lubrina Set Up Carefully clean off the outside of the...

Page 20: ...ghtly to begin cleaning and lubricating the chuck Hold it in place for about 5 seconds A beep sounds when the procedure is finished A series of beeps signals an error In this case try again Oil will s...

Page 21: ...type of handpiece and coupling there could be a release of oil mist In this case lower the pressure to 0 3 MPa Attach a handpiece to its coupling with the chuck facing back See photo Spray can A is f...

Page 22: ...ing that does not have a handpiece attached to it This would result in oil spraying out when the Start Switch is pressed Do not select a coupling that does not have a handpiece attached to it Otherwis...

Page 23: ...completed their lamps will go out a beep will sound and the Finished Lamp will light up Open the front door and remove the handpieces Hold the handpiece with one hand and push up the release ring with...

Page 24: ...ode with more oil and the long blow out mode to remove excess oil more thoroughly Short Mode For less oil The selector switch lamp blinks at 0 3 second intervals Lubrication time for one handpiece is...

Page 25: ...3 Now press the Selector Switch to change modes Each press of the Selector Switch will change the modes in sequence The lamp s blinking rate will change 4 Check the time setting by how fast the lamp b...

Page 26: ...mage the coupling For handpieces not made by Morita do not fail to use the correct Lubrina coupling or the coupling for the main tube Do not use couplings made for maintenance equipment other than the...

Page 27: ...the pin on the right side Take care not to cut your finger on the hardware Hold the door securely and pull it off carefully Excessive force could damage it Fit the door back onto the pin on the right...

Page 28: ...scolor or damage plastic and corrode metal Oil Pad Replacement Inspect the oil pad once a week and replace it before oil reaches the top Remove the oil pad case Take the pad out of the case and replac...

Page 29: ...egulator and turn it until the pressure drops to 0 MPa If the drain valve is opened without releasing the pressure inside the regulator the water in the drain could spray out into your eyes 2 Put a co...

Page 30: ...will cause it to rust Do not use disinfectants that contain chlorine based cleaners or benzalkonium chloride or chlorinated aromatics These solutions will corrode the tray If this tray is not cleaned...

Page 31: ...ing could crack the plastic parts See page 24 Coupling Replacement for how to attach couplings An O ring could slip out of its groove Make sure all O rings are properly seated in their grooves before...

Page 32: ...r details 1 Power Supply Cord Inspect visually for wear and broken wires 2 Main and Operation Switches Turn main switch on and check that main lamp lights up Check that the unit operates correctly 3 O...

Page 33: ...air Air regulator not set right Set regulator properly Unusual odor Surfaces are unusually dirty Use without connecting handpiece Select only couplings that have a handpiece connected Oil pad is satur...

Page 34: ...r local dealer or J MORITA OFFICE Disposal of Medical Devices Any medical devices which could possibly be contaminated must be first decontaminated by the responsible doctor or medical institution and...

Page 35: ...fore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment Radiated disturbance CISPR 11 Group 1 Class B This device is suitable for use in all esta...

Page 36: ...ine s to earth Signal input output 1 2 kV line s to earth Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on...

Page 37: ...ecommended separation distance in meters m Field strengths from field RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range...

Page 38: ......

Page 39: ......

Page 40: ...Pub No H5036 EN EUR 9 Printed in Japan...

Reviews: