38

11 Technical Specifications

Instructions for Use  2019-04-22

a)  Engaged person (peoples) in dental clinic

b)  Language Understanding: English or other languages offered in the Instruction for Use. 

 

 

Understanding of precautions and warnings.

c)  Experience: Not relevant

11.2 Intended User

11.3 Symbols

Manufacturer

Date of manufacture

Serial number

GS1 DataMatrix

Power switch

Standby

Oil mark

No open flame

General warning sign

Warning;  

Flammable material

Refer to instructions for 

use

Ventilation required

This way up

Keep away from rain

Fragile

Temperature limitation

Humidity limitation

Atmospheric pressure limi-

tation

Prescription Device 

CAUTION: Federal law restricts 

this device to sale by or on the 

order of a dentist.  

(Valid only for U.S.A.)

cTUVus certification mark

 

(Valid only for U.S.A. and 

Canada)

CE marking 

Conforms with the European Di-

rective, 93/42/EEC and 2011/65/

EU

Authorized representative 

in the European Commu-

nity

Marking of electrical 

equipment in accordance 

with the European direc-

tive 2012/19/EU (WEEE) 

* Some symbols may not be used.

Summary of Contents for Lubrina 2

Page 1: ......

Page 2: ......

Page 3: ...people read this manual thoroughly before using the device and pay close attention to warnings and cautions Keep this manual in a readily accessible place for quick and easy reference Trademarks and...

Page 4: ...r Tube 12 6 1 3 Power Cord 13 6 2 Spray Cans 14 6 2 1 Spray Stands 15 6 2 2 Spray Cans 16 6 2 3 Spray Stand Adjustment 17 6 3 Couplings 18 6 4 Oil Absorbent Sheet 19 6 5 Oil Collection Tray and Oil Ab...

Page 5: ...r 30 8 3 Parts Replacement 31 8 3 1 Oil Absorbent Sheet 31 8 3 2 Oil Absorbent Pad 31 8 3 3 Door Oil Absorbent Sheet 31 8 3 4 Nozzle Skirt 32 8 3 5 Coupling O rings 32 8 3 6 Spray Cans 32 9 Troublesho...

Page 6: ...fessionals Do not use the Lubrina 2 for purposes other than lubrication and flushing as part of handpiece maintenance The term flushing as used in this manual means ejecting and removing cutting debri...

Page 7: ...n us ing or cleaning the device If the device will not be used for a while unplug the power cord plug from power outlet and close the air supply valve These precautions are especially critical for saf...

Page 8: ...tal handpieces Intended Use Usage Flow To prevent the spread of grave life threatening diseases like HIV and hepatitis B be sure to autoclave handpieces after performing maintenance using the Lubrina...

Page 9: ...nying Items Parts of Device and Consumables Oil Absorbent Pad Qty 1 Oil Absorbent Sheet Qty 1 Spray Stands Qty 2 Power Cord Qty 1 Air Tube Qty 1 Door Oil Absorbent Sheet Qty 1 Cord type and plug shape...

Page 10: ...rts Identification and Function Operation Panel Front Door Front Side Rear View Air Regulator Rear Cover R Rear Cover L Front View Spray Stand Power Cord Couplings sold separately Chuck Lubrication Un...

Page 11: ...dpieces recommended for Mode 1 but it may remain excess oil inside the hand piece when the maintenance is completed Start Stop Switch Mode 1 Selection Switch Press this switch to start or stop lubrica...

Page 12: ...Operation Lamp This lights up when handpiece lubrication is in progress Line Selection Lamps Each lamp lights up when the correspond ing line is selected When performing the lubrication the correspon...

Page 13: ...jected to high temperatures Doing so could cause the spray cans in stalled to catch fire or explode Install the main unit in a well ventilated place and ventilate it regularly Place the device on a le...

Page 14: ...nexpectedly 3 Give the air tube a light tug to make sure it is properly connected Then supply air by opening the main air valve Do not give the air tube a hard pull Otherwise the unit may tip over Mak...

Page 15: ...4 Pull up the adjustment dial of the air regulator and then rotate it to adjust the air pressure between 0 3 MPa and 0 5 MPa Recommendation 0 4 MPa Increase Decrease Air Pressure Do not set the air pr...

Page 16: ...es 3 4 1 J MORITA s Maintenance Sprays MORITA MULTI SPRAY Universal Oil Spray 3 Maintenance sprays from other manufacturers that have the same can shape W H Service Oil F1 etc 2 Other manufacturers ma...

Page 17: ...lume and make sure the protrusion hub in the middle of the spray stand is correctly facing up or down de pending on the spray can as shown in the table below and then set it straight down To replace t...

Page 18: ...earing handpieces e g ASTRON CLEANER from J MORITA Doing so will damage the Lubrina 2 and handpieces Make sure the lock levers are all the way up Otherwise improper connection results in not supplying...

Page 19: ...pray stand To adjust the height rotate the adjusting screw located in the center of the spray stand with a hex wrench 1 Turn the lock lever down in clockwise direction 2 Check that the lock lever is h...

Page 20: ...pen the front door and check that mode setting and coupling type are matched Set the coupling s thick pipe to the right side and in sert the coupling into the connector p 9 5 2 1 Recommended Mode 2 Pu...

Page 21: ...k that the longer direction is oriented towards the front side of the unit The sheet can be installed either way up Oil Absorbent Pad Oil collection tray is not properly inserted Oil Collection Tray O...

Page 22: ...sheet can be set in place Magnets Front Door Front Door Line up the magnets with the metal bumps of the sheet stopper Front Door Sheet Stopper Door Oil Absorbent Sheet 1 Insert the front door sheet s...

Page 23: ...spray cans installed 7 2 Maintenance Categories Maintenance categories for the Lubrina 2 are shown in the table below p 26 7 3 4 Switching Maintenance Mode Maintenance Category Purpose Applications p...

Page 24: ...so could damage the nozzle If the handpiece is removed from the chuck nozzle before the single sustained beep it may result in scattering a huge amount of oil If the nozzle skirt comes off be sure to...

Page 25: ...nce The corresponding lamps will light up based on the selected lines Example The illustration above shows that Mode 1 is selected for Line 1 To cancel the line selection press the Line Selection Swit...

Page 26: ...might spray out into your eyes 3 When lubrication for the all selected lines is completed a single sustained beep will sound and the com pleted Line Selection Lamps and Completion Lamp will light up I...

Page 27: ...old the attachment with one hand push the release button with the other and pull the attachment out Wipe excess oil from the handpiece with a soft cloth or gauze after the maintenance Be careful not t...

Page 28: ...Mode 2 Hold down the desired Line Selection Switch and press the Start Stop Switch for about two seconds until you hear a single sustained beep The Line Selection Lamp and currently set Lubrication M...

Page 29: ...where the handpiece is attached Air Blow Mode starts after approximately two seconds You can release the switch when the process starts The process automatically stops after 30 seconds You can stop th...

Page 30: ...ustained beep will sound and the Line Selection Lamp for the completed line and the Completion Lamp will light up Wipe excess oil from the handpiece with a soft cloth or gauze after the maintenance 3...

Page 31: ...Door Oil Absorbent Sheet and Front Door Sheet Stopper Order parts from your local dealer or J MORITA OFFICE Reinstall all parts after cleaning Do not use disinfectants that contain chlorine based clea...

Page 32: ...antities of water come out there could be a problem with the air compressor and it may result in poor maintenance Contact your local dealer or J MORITA OFFICE p 12 6 1 2 Air Tube Air Regulator Front D...

Page 33: ...te Do not use a pad with excessive oil absorption Doing so could cause more oil mist to come out from the device and spray into your eyes Dispose of used door oil absorbent sheets according to regulat...

Page 34: ...in the illustra tion 8 3 5 Coupling O rings 8 3 6 Spray Cans 1 Remove the old O rings with a pair of tweezers or another such tool 2 Set the new O rings according to coupling grooves Replace the can w...

Page 35: ...front door is dislocated or the hinge is not insert properly Remove the front door and reinstall it Make sure you insert the hinge straight until it snaps on p 30 Process stops before lubri cation Se...

Page 36: ...a p 12 Handpiece is attached in an improper direc tion Set the handpiece direction correctly p 23 Air pressure setting is too high Adjust the regulator and set the pressure within the specified range...

Page 37: ...el Electrical Wirings Any medical devices which could possibly be contaminated must be first decontaminated by the responsible doc tor or medical institution and then be disposed of by an agent licens...

Page 38: ...Instructions for Use 2019 01 16 Oil Absorbent Pads Qty 5 Code No 7373465 Oil Absorbent Sheets Qty 5 Code No 7376847 Door Oil Absorbent Sheets Qty 5 Code No 7376839 Nozzle Skirt Qty 1 Code No 7373791...

Page 39: ...m x Depth 300 mm x Height 365 mm Specifications and appearance are subject to change without notice due to improvements Manufacturer J MORITA MFG CORP Used to maintain optimum performance and prolong...

Page 40: ...arning Flammable material Refer to instructions for use Ventilation required This way up Keep away from rain Fragile Temperature limitation Humidity limitation Atmospheric pressure limi tation Prescri...

Page 41: ...ic disturbances This is a Group 1 Class B product according to EN 55011 CISPR 11 This means that this device does not generate and or use internationally radio frequency energy in the form of electrom...

Page 42: ...0 5 kV 1 kV 2 kV line s to earth Signal input output 1 2 kV line s to earth Mains power quality should be that of a typical commercial or hospital environ ment Voltage dips short interruptions and vol...

Page 43: ...ac cording to the transmitter manufacturer E is the compliance level in V m and d is the recommended separation distance in meters m Field strengths from field RF transmitters as determined by an elec...

Page 44: ...42 Instructions for Use 2019 01 16 None Essential Performance Cable Length No Interface s Max Cable Length Shielding Cable Classification 1 AC Power Cable 2 3 m 3 wire Un shielded AC Power Line...

Page 45: ...43...

Page 46: ...44...

Page 47: ...45...

Page 48: ...Pub No K325 91001 505 EN Printed in Japan...

Reviews: