Operator Manual
DigiBook 150
29
Rev. 1.00-C
The machine cannot be without
air compressed when the glue
station is still hot.
Without air compressed inside the ma-
chine, the valve that handles the glue
spilling in the head could open damaging
itself.
Clean the nozzle of the glue sta-
tion and of the tank as described
in the following chapters.
Any failure to comply with these proce-
dures will make void the guarantee of
the machine.
On premelter and on glue nozzle
use the temperatures suggested
by glue producer.
Avoid opening the lid frequently,
the moisture in the air damages
the features and durability of the
glue.
The depletion of the glue is
found in two ways:
the lack of glue on the book;
issuing at the extrusion zone glue
clear glue mixed with air vents
and glue bubbles.
When you finish the glue and in-
sert a new cartridge you have to
wait about 20 min before the
new glue melts.
The machine is not operational
until the set temperature is
reached and the time set by the
manufacturer is elapsed.