5
(TA-Ts)
℉
+2
0
Operation conditon
compressor off with a delay of 1 minute
compressor on
When TA
≤
TS (lasting 1 minute), compressor off
When T1>TS+2
℉
, compressor on
The Ion/ Timer/ Sleep/ Energy Saver/ Follow Me functions are valid at the cooling mode.
2.6 Auto-defrosting function protection as below:
When TE is lower, it means that the evaporator frosts. Then the unit starts defrosting, and the indoor fan
keeps working at the moment. When the temperature is up, the unit stops defrosting.
TE
℉
55
30
compressor off
when TE is lower than 30
℉
lasting for 5 seconds
compressor on
2.7 Heating mode
The setting temperature from 62~86
℉
(17~30
℃
)
On heating mode, Lo/Mid/HI/Auto speed can be chose.
When unit uses 115V heater for heating, it will operate at Low speed (on heating mode, the speed can’t
be controlled, it should be at Low speed by force).
When unit uses 115V heater for heating, it will operate on Auto heat mode at low speed by force no
matter that the LED displays as Auto speed.
On heating mode, ION/Sleep/Timer/Follow me function are valid.
Heating operation is according to the difference between TS and TA. (figure as below)