5 Troubleshooting 

In general, possible trouble is classified in three kinds. One is called Starting Failure which is caused from an 
electrical defect, another is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper 
application, and the other is called the Structure Damage. 
 
5.1 Troubleshooting 

Problem 

Solution 

Air conditioner does not 

start 

Wall plug disconnected. Push plug firmly into wall outlet. 

House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit 

breaker. 

Plug Current Device Tripped. Press the RESET button. 

Power is OFF. Turn power ON. 

Air from unit does not feel 

cold enough 

Room temperature below 62

(17

). Cooling may not occur until room temperature rises above   

62

(17

).       

Temperature sensing element touching cold coil, located behind air filter. Straighten tube away 

from coil. 

Set to a Lower temperature. 

Compressor stopped when changing modes. Wait for 3 minutes after set to the COOL mode. 

Air conditioner cooling, but 

room is too warm- ice 

forming on cooling coil 

behind decorative front. 

Outdoor temperature below 64

(18

). To defrost the coil, set FAN ONLY mode. 

Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN 

ONLY mode. 

Thermostat set too cold for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then, 

set temperature to a Higher setting. 

Air conditioner cooling, but 

room is too warm- NO ice 

forming on cooling coil 

behind decorative front. 

Dirty air filter- air restricted. Clean air filter. Refer to Care and Cleaning section. 

Temperature is set too High, set temperature to a Lower setting. 

Air directional louvers positioned improperly. Position louvers for better air distribution. 

Front of units is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage 

in front of unit. 

Doors/ windows/registers, etc. Open- cold air escapes. Close doors, windows, registers. 

Unit recently turned on in hot room. Allow additional time to remove. Stored heat from walls, 

ceiling, floor and furniture. 

Air conditioner turns on and 

off rapidly 

Dirty air filter- air restricted. Clean air filter 

Outside temperature extremely hot. Set FAN speed to a Higher setting to bring air past cooling 

coils more frequently. 

Noise when unit is cooling 

Air movement sound. This is normal. If too loud, set to a slower FAN setting. 

Window vibration - poor installation. Refer to installation instructions or check with installer. 

Water dripping INSIDE 

when unit is cooling. 

Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to 

installation instructions - check with installer. 

Water dripping OUTSIDE 

when unit is cooling. 

Unit removing large quantity of moisture from humid room. This is normal during excessively 

humid days. 

Remote Sensing 

Deactivating Prematurely 

(some models) 

Remote control not located within range. Place remote control within 20 feet & 180°, radius of the 

front of the unit. 

Remote control signal obstructed. Remove obstruction. 

Room too cold 

Set temperature too low. Increase set temperature. 

 

Summary of Contents for TM08CEM9115S

Page 1: ...m inch TTW 615 24 2 369 14 5 515 20 3 TTW sleeve 649 25 6 388 15 3 445 17 5 Windows AC TTW SERVICE MANUAL TTW sleeve TM08CEM9115S TM08CM10115S TM10CEM9230S TM10CM10115S TM10CM10230S TM12CEM9230S TM12C...

Page 2: ...otection function 4 2 3 Auto mode 4 2 4 Fan only mode 4 2 5 Cooling mode 4 2 6 Auto defrosting function protection as below 5 2 7 Heating mode 5 2 8 Dry mode 6 2 9 Sleep mode 6 3 Internal Structures 7...

Page 3: ...1 1 Operation Modes and Instructions 1 1 Display control ELECTRONIC HEATING MODELS COOLING ONLY MODELS...

Page 4: ...ress to change the fan speed each time you press the button the fan speed in four steps Auto Low Med and High The fan speed can t be adjusted under HEAT mode On Dry mode the fan speed is controlled at...

Page 5: ...ature point the remote control towards the unit and press the Follow Me button The remote display is actual temperature at its location The remote control will send this signal to the air conditioner...

Page 6: ...ll choose actual operation mode in auto mode in the below cases Power on or change mode to auto mode or adjust temperature in auto mode the unit will choose actual running mode again A On auto mode if...

Page 7: ...unit stops defrosting TE 55 30 compressor off when TE is lower than 30 lasting for 5 seconds compressor on 2 7 Heating mode The setting temperature from 62 86 17 30 On heating mode Lo Mid HI Auto spe...

Page 8: ...the fan speed will be change to auto fan In this function the first and second 30minuts the setting temp will up or down for heating mode 2 1 after that will keep 6 hours until the function stop When...

Page 9: ...7 3 Internal Structures...

Page 10: ...Tapered Space Blocks are different as shown below 1 Fedders of Friedrich 16 3 4 Deep Tapered Spaceer Blocks is cut into three pieces as shown below 2 General Electra Hotpoint 16 7 8 Deep Tapered Spac...

Page 11: ...eaning filter Notice The air filter should be checked at least once a month to see if cleaning is necessary Trapped particles in the filter can build up and cause an accumulation of frost on the cooli...

Page 12: ...orming on cooling coil behind decorative front Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too High set temperature to a Lower setting Air di...

Page 13: ...3 73 4 10 9731 50 122 3 451 3 26 6 41 5878 24 75 2 10 4736 51 123 8 3 3185 2 28 4 39 8239 25 77 10 52 125 6 3 1918 1 30 2 37 1988 26 78 8 9 5507 53 127 4 3 0707 0 32 35 2024 27 80 6 9 1245 54 129 2 2...

Reviews: