![MOOVAIR TM08CEM9115S Service Manual Download Page 6](http://html1.mh-extra.com/html/moovair/tm08cem9115s/tm08cem9115s_service-manual_1832628006.webp)
4
2 Electronic function
2.1 Terms and definitions
TA: Temperature of indoor ambient (T1)
TE: Temperature of evaporator (T2).
TS: The set temperature.
DAHT: Sensor of heater
2.2 Protection function
The compressor restart protection functions with a delay of 3 minutes.
5 minutes operation for compressor(this function is for cooling and heat pump mode)
Sensor protection at open or short circuit.
2.3 Auto mode
At Auto mode, the unit will choose cooling, heating or fan-only mode according to ΔT =TA-Ts)
ΔT=TA-Ts
Running mode
ΔT
>
4
F
Cooling
-2
F≤ΔT≤4
F
Fan-only
ΔT<-2
F
Heating (Setting temperature is TS-1
F);
Or Fan-only (for cooling only models).
The unit will choose actual operation mode in auto mode in the below cases:
Power on or change mode to auto mode or adjust temperature in auto mode, the unit will choose actual
running mode again.
A: On auto mode, if the compressor keeps not running for 15 minutes. judge condition B
B: If ΔT<-8
℉
or ΔT
>
2
℉
, the unit will choose actual running mode again according to ΔT till the
compressor stops.
2.4 Fan-only mode
The temperature can’t be controlled at the mode, and the room ambient temperature is display on LED.
The Ion/ Timer functions are valid at the fan-only mode.
And follow me function (for some models) is invalid at fan-only mode.
2.5 Cooling mode
The temp can be set from 62 to 86
℉
(17 to 30
℃
)
The compressor will be activated by sensing the difference between setting temperature and the actual
ambient room temperature.
The compressor operates as below:
Summary of Contents for TM08CEM9115S