![Moore Industries TMZ User Manual Download Page 8](http://html1.mh-extra.com/html/moore-industries/tmz/tmz_user-manual_1832398008.webp)
8
The Interface Solution Experts
TMZ
PC-Programmable MODBUS
Temperature Transmitter
Figure 4.
Hooking-Up the TMZ (TPRG)
Configuring the TMZ
One of the benefits of the TMZ is that there are no
internal or external controls to adjust or settings to
change. All operating parameters are set using a
PC and Moore Industries’ Intelligent PC Configuration
Software.
The software settings are downloaded to the
transmitter in the form of a Configuration File and
stored in the instrument’s memory. You can save a
backup copy of the file on your PC hard drive or disk.
The transmitter communicates with the PC through an
RS-232 connection to the PC’s serial port or through
the MODBUS output with a fixed baud rate at 19.2k.
1
2
3
4
COM
TMZ
PROGAMMABLE
MODBUS
TRANSMITTER
READY
INPUT
MILLIVOLT
SOURCE
OR T/C
SIMULATOR
_
+
OHMS OR
2-WIRE
RTD
SIMULATOR
24Vdc
POWER
SUPPLY
–
+
A
B
S
MODBUS OUTPUT
TO SERIAL
(COM) PORT
OF PC
MODBUS Host
RS-485/RS-232
Converter
3-Wire RTD or
Decade Resistance Input
4-Wire RTD or
Decade Resistance Input
Potentiometer Input
INPUT HOOKUP CONNECTIONS
OHMS
OR RTD
SIMULATOR
OHMS
OR RTD
SIMULATOR
PC
TO SERIAL
(COM) PORT
OF PC
OR
To USB
(COM)
Port of PC