 TMZ

PC-Programmable MODBUS  

Temperature Transmitter

Specifications

 

Input Accuracy:

   

See Table 4 

Overall Accuracy:

  The 

overall accuracy of the 
unit is the input accuracy.  
It includes the combined 
effects of linearity, 
hysteresis, repeatability and 
adjustment resolution.  It 
does not include ambient 
temperature effect.  For  
T/C input, add the RJC 
error.

 

Cold Junction 
Compensation Accuracy 
(T/C Inputs Only):  

±0.45°C

  

Stability:  

See Table 1  

Response Time:  

INPUT 

UPDATE TIME: 128msec; 
MODBUS POLLING TIME:  
Dependent upon how fast 
and how often a MODBUS 
master requests data 

Isolation:

  Standard unit, 

1000Vrms between case, 
input.  1500Vrms between 
power and input; WITH  
-RF OPTION, 500Vrms 
between case, input and 
power.  

Power Consumption:  

 

1W max.

 

Input Impedance:  

 

T/C and mV inputs, 
40Mohms, nominal

 

Input Over-Range 

Protection:  

±5Vdc

 

Excitation Current (RTD 
and Ohm Inputs Only):  

250µA, ±10%

 

 

 

Type:  

Standard 

MODBUS RTU protocol 
interface over RS-485 
(parameters as specified 
in U.S. Standard EIA-
RS485) 

Address Range:  

Configurable from 1 to 
247.  Unit will assume a 
MODBUS address of 01 
by default. 

Baud Rates:

  Interface 

supports the following:  
300, 600, 1200, 2400, 
4800, 9600, 19.2k and 
38.4k 

Character Format:

  One 

start bit, 8 data bits and 
one stop bit

LED Type: 

 INPUT LED:  

Dual color LED indicates 
input failure 
READY LED:  Green LED 
indicates unit is operating 
properly 

Performance

Indicators

Ambient 

Conditions

Weight

Performance 

(continued)

Specifications and information subject to change without notice.

Communications

Operating & Storage 
Range:

  -40°C to +85°C  

(-40°F to +185°F) 

Effect of Ambient 
Temperature on Cold 
Junction Compensation 
(T/C Inputs Only): 

 

±0.005°C per °C change 
of ambient temperature 

Relative Humidity:

   

0-95%, non-condensing 

Ambient Temperature 
Effect:

  See Table 3  

RFI/EMI Immunity 
(Standard Unit):

   

10V/m@20-1000MHz, 
1kHz when tested 
according to  
IEC1000-4-3-1995 
WITH -RF OPTION, 
30V/m@20-1000MHz, 
1kHz AM when tested 
according to  
IEC1000-4-3-1995 

Noise Rejection: 

Common mode, 
100dB@50/60Hz; Normal 

mode, Refer to Table 2

290 g (10.2 oz)  

Table 1.  

Long-Term Stability 

RTD, Ohm & Pot Inputs 

Input-to-Output (Years)

Stability  

(% of maximum 

span)

 

3

5

0.09

0.08

0.16

0.14

0.21

0.18

T/C & mV Inputs

Table 2.  

Normal Mode Rejection Ratio

150mV

80mV

250mV

1V

500mV
100mV

1V 

 

250mV
100mV

T/C: J, K, N, C, E

T/C: T, R, S, B

Pt RTD: 100, 200, 300ohms

Pt RTD:  400, 500, 1000ohms

Ni: 120ohms 

Cu: 9.03ohms 

 

Sensor Type

Max. p-p Voltage Injection for 

100dB at 50/60Hz

 

mV 

 

250-1000 

 

62.5-250 

 

31.25-62.5

Resistance

1-4kohms

0.25-1kohms

0.125-0.25kohms        

Table 3.

 

Ambient Temperature Effect

Input Type

*RTD 

 

Millivolt 

 

Ohm 

0.0035°C 

 

0.5µV + 0.005% of reading 

 

0.0 0.005% of reading

 

*Accuracy of Ni672 is 0.002°C

Thermocouples

Accuracy per 1°C (1.8°F) change in Ambient

 

 

 

 

R, S 

 

 

 

 

mV

0.00016°C + 0.005% of reading 

 

0.0002°C + 0.005% of reading 

 

0.00026°C + 0.005% of reading 

 

0.0001°C + 0.005% of reading 

 

0.00075°C + 0.005% of reading 

 

0.0038°C + 0.005% of reading 

 

0.0003°C + 0.005% of reading 

 

0.00043°C + 0.005% of reading 

 

0.5µV + 0.005% of reading

Accuracy per 1°C (1.8°F) change in Ambient

Input Type

Summary of Contents for TMZ

Page 1: ...2016 225 720 02D All product names are registered trademarks of their respective companies TPRG PC Programmable MODBUS Temperature Transmitter Left TMZ TPRG PC Programmable MODBUS Temperature Transmit...

Page 2: ...Numbers 4 Specifications 5 Dimensions 7 Configuring the TMZ 8 Installing the Configuration Software 9 Connecting the TMZ to the PC 9 PC Configuration Software Summary 10 Status and Tool Bar Legend 11...

Page 3: ...ation 16 Mounting the TMZ 16 Making the Electrical Connections 16 Recommended Ground Wiring Practices 16 CE Conformity 16 Operation 16 Maintenance 16 Customer Support 16 Appendix A TMZ MODBUS Register...

Page 4: ...gital output and retains the high accuracy of an Analog to Digital converter without the limitation of low resolution which is associated with analog outputs The multi drop nature of the RS 485 port a...

Page 5: ...Performance continued Specifications and information subject to change without notice Communications Operating Storage Range 40 C to 85 C 40 F to 185 F Effect of Ambient Temperature on Cold Junction...

Page 6: ...2 F n a 240 to 960 C 400 to 1760 F 150 to 720 C 238 to 1328 F 240 to 580 C 400 to 1076 F 100 to 360 C 148 to 680 F 65 to 280 C 85 to 536 F 0 4095ohms 0 100 210 to 770 C 346 to 1418 F 270 to 1390 C 454...

Page 7: ...D WHEN INSTALLED 1 2 3 4 COM TMZ PROGAMMABLE MODBUS TRANSMITTER READY INPUT 25mm 1 00 in 138mm 5 43 in 133mm 5 24 in 4 97 in 126mm Top View Bottom View MODBUS NOT USED NOT USED A 1 2 3 4 B S MODBUS IN...

Page 8: ...s memory You can save a backup copy of the file on your PC hard drive or disk The transmitter communicates with the PC through an RS 232 connection to the PC s serial port or through the MODBUS output...

Page 9: ...MZ This makes it easy to create a set of operating parameters save them to disk and download them to one or more transmitters at a later time The TMZ must be connected to the PC in order to perform se...

Page 10: ...ed unit 3 Device ID Displays your unit configuration HLPRG TPRG ID Hardware revision and Software revision 4 Identification Parameters Use this parameter to place an identifying Tag 8 alphanumeric cha...

Page 11: ...this tab to set your input parameters Refer to the Input section for a complete description 11 Trimming This parameter allows you to configure and perform sensor trimming Refer to the Trimming sectio...

Page 12: ...d in the Transfer dropdown menu located in the Status Bar You may also download by clicking the button in the Tool Bar You may also use the Quick Set feature to configure your Input parameters and dow...

Page 13: ...ng the appropriate button Each pair consists of Set and Trim values 2 Enter the values that need to be trimmed into the Set Value field and click Set 3 Apply the targeted signal to the input wait unti...

Page 14: ...Click the Enabled box 2 Select the number of points for your curve 32 points maximum 3 Type your individual values in the X and Y columns Source variables are inserted into the X column while the corr...

Page 15: ...By default the assigned MODBUS address is 01 Baud Rate The speed of data transmission It should be set to match the baud rate of the attached controller Supported Baud Rates include 300 600 1200 2400...

Page 16: ...e original sale Mounting the TMZ The TMZ can be mounted on standard DIN mounting rails Making the Electrical Connections Please refer to Figure 4 for electrical connections Recommended Ground Wiring P...

Page 17: ...fRange R Percent of Range floating point 262 263 ScaledPV R Scaled PV floatpoint 264 265 LinearedPV R Linearised PV floating point 266 ErrorStatus R TMZ Error Status Word Status Bit Description 0 Conf...

Page 18: ...E BUYER WITH THE COMPANY DO NOT IMPLY THAT THE COMPANY WARRANTS THE GOODS OR SERVICES IN ANY WAY ANY BUYER OF GOODS OR SERVICES FROM THE COMPANY AGREES WITH THE COMPANY THAT THE SOLE AND EXCLUSIVE REM...

Page 19: ...he TMZ TPRG User s Manual 225 720 02 This document addresses the TMZ 2TPRG dual input model of the TMZ The TMZ 2TPRG has two individually configurable sensor inputs and a single isolated MODBUS output...

Page 20: ...rameters as specified in U S Standard EIA RS485 Address Range Configurable from 1 to 247 Unit will assume a MODBUS address of 01 by default Baud Rates Interface supports the following 300 600 1200 240...

Page 21: ...ut 2 Wire RTD or Decade Resistance Box 1 4 3 2 3 Wire RTD or Decade Resistance Box 4 Wire RTD or Decade Resistance Box 1 4 3 2 Potentiometer Input 100mm 3 94 in 102mm 4 03 in 45mm 1 77 in 5 25 in 133m...

Page 22: ...e RTD or Decade Resistance Input 4 Wire RTD or Decade Resistance Input Potentiometer Input INPUT HOOKUP CONNECTIONS OHMS OR RTD SIMULATOR OHMS OR RTD SIMULATOR TO SERIAL COM PORT OF PC OR To USB COM P...

Page 23: ...tolerance range 4 Process Variable PV Displays the values of the process variables that are being monitored 5 Identification Parameters Use this parameter to place an identifying TAG 8 alphanumeric c...

Page 24: ...In appearance windows for both Input 1 and Input 2 are the same They are configured similarly for the specific input chosen Configuration of the Input windows follows the general parameters with slig...

Page 25: ...configuring To scale the zero and full range span of your sensor perform the following steps in the SENSOR RANGE parameter 2 Place the value you want displayed as the low or zero end of your range in...

Page 26: ...range channel 1 float Percent of range channel 2 float TMZ dual input status information TMZ dual input additional status information TMZ on line 0 off line 1 mode Model Type 0 low level single input...

Reviews: