![Moons' M2 Series Quick Setup Manual Manual Download Page 7](http://html.mh-extra.com/html/moons/m2-series/m2-series_quick-setup-manual-manual_1832296007.webp)
7
Rev. 1.0
4/29/2016
M2 Quick Setup Guide Manaul
2 Installation
2.1 Storage Conditions
Some Storage suggestions are followed:
•
Correctly packaged and store in a clean and dry ,avoid direct sunlight
•
Store within an ambient temperature range of -20
℃
to +65
℃
•
Store within a relative humidity rang of 10% to 85% and non-condensing
•
Don
’
t store in a place subjected to corrosive gasses
2.2 Installation Conditions
The operation ambient conditions are followed:
•
Temperature range of 0
℃
to 50
℃
. If the ambient temperature of servo drive is greater than
45
℃
, please install the drive in a well-ventilated location
The ambient temperature of servo dive for long-term reliability should be under 45
℃
.
•
The servo drive and motor will generate heat. If they are installed in a control panel, please
ensure suf
fi
cient space around the units for heat dissipation.
•
Operation within a relative humidity rang of 5%to 85% and non-condensing
•
The vibration lower than 5.88m/s
2
, 10-60Hz(Do not continuously use the drive for along time at
resonance point.)
•
Don
’
t mount the servo drive and motor in a location subjected to corrosive gasses or
fl
ammable gases, and combustibles.
•
Please mount the servo drive and motor to a indoor electric control cabinet without liquid and
direct sunlight
•
Don
’
t mount the servo drive and motor in a location subjected to airborne dust.
2.3 Drive Dimensions(Unit: mm)
50W
、
100W
、
200W Type
M2DV-1D8
145
41
35.5
5
6
5
150
140
Ø5
400W Type
M2DV-3D0
Ø5
145
5
6
5
55
49.5
150
140
750W Type
M2DV-4D5
Ø5.2
176
65
57.5
7.5
5.2
150
140
5