M2 Quick Setup Guide Manaul
6.3 Motor Configuration Manually
Before JOG mode operation, M2 series AC servo drive requires motor con
fi
guration setup. To
con
fi
rm your motor speci
fi
cation, please refer to chapter 2.3.
For more MOONS
’
motor information, please refer to appendix 1.
For example: To setup a drive for model: SM0402AE4-KCD-NNV09 motor. these are the following
steps:
Step
Display
Details
1
Press
into the Function Parameters mode at the Monitor Status mode
2
Press the
and
key to select F07(MC)
3
Press
key into value setting mode.
4
Press
、
key to change value.
5
Press and hole
key for 1 second to con
fi
rm motor con
fi
guration.
6
7
Parameter is effective only after the servo drive is restarted.
6.4 Operations of JOG Mode
Step
Display
Details
1
Press
to switch the Monitor Status mode into the Drive Parameters
Con
fi
guration mode
2
Scroll
、
key to select parameter P61(SI)
3
Press
key into value setting mode
4
Scroll
、
key to change values.
5
Press and hold
key for 1 second to con
fi
rm the setting value.
6
Press
key into the Function Operation mode.
7
Scroll
、
key to select Function F06(MC) to enable the motor.
8
Press and hold SET key for 1 second, the drive will be enabled. The last dot will
light to shows the drive is enabled.
9
Scroll the
、
key into function F01(CJ) to run JOG mode.
10
Press the
key into JOG mode
11
Press the
key ,the motor will rotate at CW direction with the speed 1rps.
12
Press the
key ,the motor will rotate at CCW direction with the speed 1rps.
13
Press the
key to stop the motor
14
Press the
key back to the Function Operation mode.