3
0746-SOM-00002 - 02
© Tritech International Ltd.
Acoustic Specifications
Operating frequency
720kHz
1200kHz
Angular resolution
1.0° acoustic, 0.25° effective
0.6° acoustic, 0.12° effective
Range
0.1 m – 120 m
0.1 m – 50 m
Number of beams
512
1024
Horizontal Beam Aperture
120°
Fwd 65° or 120°
Vertical Beam Aperture
20° (+/-10° about horizontal)
12° (+/-6° about horizontal)
Update rate
5-65 Hz (mode & range dependant)
Range resolution
4mm
2.4mm
CHIRP support
Yes
Speed of sound
Integrated VoS sensor
Note
In high frequency (1200kHz) mode, the user has the option of switching to
using a 65° sector which will double the update rate compared to the full 120°
sector scan
Electrical and Communication
Supply voltage
19V to 74V DC
Standby Power Consumption
10W
Operational Power Consumption
15W – 30W (range dependent)
Main port protocol
Ethernet
Aux port (optional)
RS232,TTL in, pass-through power
Connector type
Impulse MKS(W)-307-FCR
The power consumption range quoted is accurate for a standalone unit and does not include cable losses.