P 428[0] - ISA00
and
P 428[1] - ISA01
can be used to assign an offset to
each
analog input separately. For details on how to use offsets,
see Section
"Analog
P 429[0] - ISA00_gain
and
P 429[1] - ISA01_gain
can be used to assign a
gain factor to each analog input separately. For details on how to use
gain factors,
"Analog input scaling" on page 2
P 429[2] - ISA00_limMin
and
P 429[3] - ISA01_limMin
can be used to
assign a lower limit to each analog input separately.
P 429[4] - ISA00_limMax
and
P 429[5] - ISA01_limMax
can be used to
assign an upper limit to each analog input separately.
The analog inputs’ compensated, filtered, and normalized values will be
available in
P 407 - CON_ANA_Isaf
.
P 665[0] - DV_CAL_IsaType
can be used to configure the analog inputs as
voltage or current inputs. This setting will apply to both inputs.
NOTE
The parameters are reinitialized only after the control has been re-
enabled or by a device restart.
ID
Index Name
Unit Description
109
0
MPRO_INPUT_FS_ISA00
Function of analog input ISA00
110
0
MPRO_INPUT_FS_ISA01
Function of analog input ISA01
405
0
CON_ANA_Filt0
ms
Analog input ISA00: Filter time constant
406
0
CON_ANA_Filt1
ms
Analog input ISA01: Filter time constant
407
CON_ANA_Isaf
Analog inputs: Values (filt, norm, comp)
407
0
ISA00
Compensated, filtered, normalized value
407
1
ISA01
Compensated, filtered, normalized value
427
0
CON_ANA_CalibZero
Analog inputs: Calibration of analog channel
offset @zero input
428
CON_ANA_Offset
Analog inputs: Offset
428
0
ISA00
V
Voltage offset for input ISA00
428
1
ISA01
V
Voltage offset for input ISA01
429
CON_ANA_Gain
Analog inputs: Gain scaling
Table 9.11: “Analog inputs” parameters
MOOG
ID
No.:
CB40859-001
Date:
02/2018
MSD
Servo
Drive -
Device
Help
2
4
4
9 Input/Output settings
ID
Index Name
Unit Description
429
0
ISA00_gain
Gain scaling for input ISA00
429
1
ISA01_gain
Gain scaling for input ISA01
429
2
ISA00_limMin
Minimum value for input ISA00
429
3
ISA01_limMin
Minimum value for input ISA01
429
4
ISA00_limMax
Maximum value for input ISA00
429
5
ISA01_limMax
Maximum value for input ISA01
665
0
DV_CAL_IsaType
Analog inputs: Switch between current/voltage
input
Table 9.11: “Analog inputs” parameters (continue)
9.4.2 Function selectors
Before using the analog inputs, they are normally associated with a special device
functionality for analog inputs. The corresponding function selectors also make it
possible to select a special digital functionality instead.
ID
Index Name / Setting
Unit Description
109-110
0
MPRO_INPUT_FS_
ISA0x
“Analog inputs” “function selectors”
PRC_REF (-14)
Process controller reference value
PRC_ACT (-13)
Process controller actual value
ENC_ANA (-12)
Analog encoder (on channel 4)
TWIN_SCALE (-11)
TWIN position scaling
HYD_Q_ACT (-10)
Hydraulic actual flow (software specific)
HYD_P_ACT2 (-9)
Hydraulic actual pressure on 2nd sensor
(software specific)
HYD_Q_REF (-8)
Hydraulic reference flow (software specific)
HYD_P_ACT (-7)
Hydraulic actual pressure (software specific)
HYD_P_REF (-6)
Hydraulic reference pressure (software specific)
VFC_REF_SCALE (-5)
VFC reference scaling 0-100 % (software
specific)
TLIM (-4)
Analog torque limit 0-100 %
OVR (-3)
Speed override 0-100 % at positioning
Table 9.12: “Analog inputs” function selectors