____________________________________________________________________
_______________________________________________________________________
MN0090-05 Page 66 of 68 18008
MPT-90 PRODUCT MANUAL
This document contains U.S. export controlled technical data as regulated by the U.S. Export Administration Regulations 15 CFR Parts 730-774, export, disclosure or transfer contrary to U.S. law is prohibited.
8.0
FAULT ISOLATION
NOTE
The Fault Isolation procedures listed in this manual should be performed in
conjunction with the Emulator/GUI software included on the CD supplied with this
unit. Refer to Section 5.0 for instructions on installing and running the Moog GUI
software and installation of the test cable.
8.1
Introduction
A visual inspection of the Pan & Tilt Unit while it is operating will usually reveal
if a problem is mechanical or electrical. Users should become familiar with
the equipment and report any unusual problems before small problems
become major ones. Straightforward, common sense troubleshooting
techniques will usually reveal the source of most problems encountered.
Users should review the following general information to assist in
troubleshooting the Pan & Tilt Unit:
8.2
Mechanical or Electrical
1) Remove the Access Covers
2) Actuate a movement using the Emulator/GUI software to determine if the
Drive Motor is running. If the motor is running, the problem is usually
mechanical. If the motor is not running, the problem can be either
mechanical or electrical.
3) Mechanically uncouple the motor by removing the Drive Chain from the
sprocket.
NOTE
If the motor operates, the problem is usually mechanical (binding Worm
Drive Gears, Drive Chain tension was too strong, etc.).