© MOOG 2019
This document is subject to MOOG INTELLECTUAL AND PROPRIETARY INFORMATION LEGEND . The details are on page II.
33
MRJ06301
Figure 1-34 Machine setup display (SHIFT
→F4)
“Figure 1-35” defines all of the settings.
Function name
Setting
Profile points
10/20/30/50/100/200
Custom
Any value between 10-200
Profile interpolation
Straight
Spline
Language
English
Chinese
Japanese
Back light (min)
5
10
30
-- (no screen saver)
LCD
Contrast. Knob CCW : dark, Knob CW : bright
Memory
ON
OFF
Password
ON
OFF
Above 7 parameters are updated always
Machine Type
Continuous
Accumulator
Servovalve type
MFB
EFB
Valve current (mA)
10
20
50
100
-- (*Note)
Open command
Disable
Enable
The above 4 parameters are updated by pressing the switch in the order of [Reboot]->[SET], by being
restarted
*Note) When [Servovalve type] is set to [EFB], it automatically becomes ± 10 V output.
Figure 1-35 Machine setting Functions
It is necessary to execute Reboot whenever you change the setting. When moving to another
screen without Reboot, the parameter returns to its original value. When you press [Reboot]
→
[SET], DigiPack
Ⅲ
will be restarted. Do not apply hydraulic pressure when executing [Reboot].