background image

Page 1

XG0305

MD34-BV Homefire

The Warranty

The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a 
ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve 
and fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation 
outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, 
and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies 
will, at its option, refund the purchase price of the Montigo Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which 
are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All 
replacement or repair components will be shipped F.O.B. the nearest The Companies factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo Gas 

Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas Appli-
ance could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of local 
building codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies 

(2)  The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such 

as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, 
expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs 
or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the 
exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty 
with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty 
lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.
The Companies Are Not Responsible For Work Done Without Written Consent
The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.
Dealers Have No Authority To Alter This Warranty
The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated 
above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably 
possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Other Rights

Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without 
notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Warranty

Summary of Contents for MD34-BV Homefire Plus

Page 1: ...or s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Warning Improper installation adjustment altera tion service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier For Your Safety Do not store or use gasoline or ...

Page 2: ...tory built gas fireplaces Installation repairs should be done by a qualified contractor Installations in Canada must conform to the current CAN CGA B 149 1 and 2 Gas Installation Code and local regulations If the optional air circulating fan kit is installed it must be electrically grounded in accordance with CSA C22 1 Canadian Electrical Code Part 1 and or Local Codes Installations in the USA mus...

Page 3: ... 15 32 30 38 Figure 2 Framing dimensions Framing 33 15 3 4 39 When sheetrock is not used behind the fireplace fram ing depth may be reduced to 15 Figure 3 Corner framing dimensions 22 42 0 clearance to corners only 33 59 3 8 Installing a Shelf Over the Fireplace When installing a shelf over the top of the fireplace the minimum al lowable clearance from the top of the fireplace to a shelf is 16 Pro...

Page 4: ...er brass trim may be connected to a wall switch The valve generates its own power on a millivolt circuit Use only low voltage wire and DO NOT connect any external power to it Refer to Figure 12 for wiring requirements Note The switch location must not exceed 30 from the fireplace Figure 4 Gas line access During any pressure testing of the gas supply piping that excedes 1 2 psig 3 5 kPa the applian...

Page 5: ... of energy has prompted us to manufacture many models of fireplaces which are hot fuel and energy efficient Please be aware temperatures over the mantel will rise above nor mal room temperature and walls above fireplace may be hot to touch We recommend careful consideration be given to the effects of elevated mantel temperatures which may be in excess of product design for example candles plastic ...

Page 6: ...L2 Figure 7a Wiring for optional air circulating fan kit Figure 7b Wiring schematic for optional fan kit Installing the Log Set The ME34 BV is supplied with four 4 soft fibre logs Logs A and B are permanently attached to a fibre base which is pre installed by the factory To install the two small logs C and D simply place them onto their mating positions as shown in figure 8a below When log set is ...

Page 7: ...y reverse the steps above Figure 9 MD34 BV insert INSET 1 Tab INSET 2 Mounting Bracket Venting Plate Front Slot Removing and Installing the Door Removing the door surround The door surround is held in place by two metal clips at the top and one magnet on each side To remove the surround pull the bottom outwards and lift upwards until the slots A are clear of tabs B in the door You may need to use ...

Page 8: ...n Model MD34 BV 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up lower trim 1 Turn off remote switch 2 Flip down lower trim 1 STOP Read the safety information above on this label 2 Flip down lower trims 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you then smell gas STOP...

Page 9: ...to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down lower trim 3 Turn the switch on the gas control to Off 4 Flip up trim 1 STOP Read the safety information above on this label 2 Flip down lower trims 3 Turn switch on th...

Page 10: ...cribed below will adjust both the main burner and the ember burner To raise the flame height turn the black knob located behind the lower trim counterclockwise To lower the flame height turn clockwise Gas Control Knob Shown in Pilot postion Hi Lo Adjustment Knob Figure 11 Hi Lo Adjustment on Model MD34 BV gas valve Cleaning When the fireplace is first activated there may be some smoking and a visi...

Page 11: ... rm er LineVo lt Sup p ly Rep lace SV9500 SV9600 Saveo ld Ig niter Flam e Ro da ssem b ly fo rservice INSET HSI Terminals C H EC K Linevo ltag ep o w er Lo wvo ltag e transfo rm er Lim itC o ntro ller Therm o stat W iring a irp ro vingsw itcho n co m b ustio nairb lo w ersystem Ventd am p er ifused iso p en andendsw itchm ad e Gas Control Valve Pilot Burner Adjustment 1 Locate Pilot Adjustment Scr...

Page 12: ...ts not manufactured or supplied by The Companies 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and und...

Page 13: ... Horizontal Trim Kits 2 4 piece fibre logset Available Options and Accessories 3 3 Fan Pack 4 Variable Speed Blower Kit 5 Hand Held Remote Control 6 3 Piece Picture Frame Surround PFO 7 4 Piece Picture Frame Surround PFS 8 Door Cover Square DF0 9 Door Cover Arched DFA 2 3 4 6 7 5 8 9 ...

Page 14: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0305 Rev 03 09 2002 ...

Reviews: