Installation

IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS

The 

Hotshot

 fireplace insert must be installed in accordance with 

these Instructions. Carefully read all the Instructions in this manual 
first. Consult the Local Gas Branch to determine the need for a permit 
prior to starting the installation. It is the responsibility of the installer to 
ensure this fireplace is installed in compliance with the manufacturers 
instructions and all applicable codes.

Due to high operating temperatures, this appliance should  be located out of traffic & 

away from furniture and draperies.

Children and adults should be alerted to the hazards of the high surface temperature, 

which could cause burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the 

appliance.

Clothing or other flammable materials should not be placed on or near the appliance.

CAUTION

When this appliance is installed directly on any combustible material other than wood 

flooring, it must be installed on a metal or wood panel extending the full width and 

depth of the appliance or a fire will occur causing serious injury,  property damage or 

even death.

DANGER

Installation and repairs should be done by an authorized gas fireplace service technician. 

The appliance should be inspected before use and at least annually by a professional. More 

frequesnt cleaning may be required due to exessive lint from carpeting, bedding material, 

etc. It is imperative that control compartments, burners and circulating air passageways of 

the fireplace are kept clean.

NOTICE

 

• Installations in Canada must conform to the local codes or in 

the absence of local codes to the current version of Natural Gas and 
Propane Installation Code, CSA B149. Electrical Installations must 
conform to the local codes or, in the absence of local codes, to the 
current version of Canadian Electrical Code, CSA C22.1.1.

• Installations in the USA must conform to the local codes or in the 
absence of local codes to the current version of National Fuel Gas 
Code, ANSI Z223.1/NFPA 54. Electrical Installations must conform to 
the local codes or, in the absence of local codes, to the current ver-
sion of the National Electrical Code, ANSI/NFPA 70.  See Appendix C 
for installation within the State of Massachusetts.

  Ensure that your masonry fireplace's opening is large enough to 

accommodate the Hotshot, see 

figure 1

 

Thoroughly clean the masonry or solid fuel fireplace and chimney 

that in which the insert will be installed.

  The appliance has a gas access hole on the left hand side, and 

it is supplied with a flexible gas connector on the left hand side of 

the insert, see

 figure 2

Before You Begin Installation 

WARNING

A barrier designed to reduce the risk of burns from hot viewing glass is provided with this 

appliance and shall be installed for the protection of children and other at-risk individuals.

If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s 

barrier for this appliance.

WARNING

Any safety screen, guard, or barrier removed for servicing an appliance must be replaced

prior to operating the appliance.

Summary of Contents for Hotshot DHS

Page 1: ...rature Strong magnetic field Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger of suffocation High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger...

Page 2: ...s 6 Clearances 7 Installing the Gasline 7 Chimney Liner Installation 8 Face Plate Trim and Louvres Face Plate Installation 9 Lower Louvre Assembly 9 Face Plate Trim 9 Upper Louvre Assembly 10 Wiring for the Air Circulating Fan 11 Removing and Installing the Screen Door 12 Installing the Logset 13 Operation 14 15 Maintenance 16 17 Warranty 19 Appendix 20 ...

Page 3: ...n a masonry fireplace equipped with a double burner glowing embers and a six piece log set The Hotshot DHS is rated for Natural Gas or Propane at 25 000 BTU H 7 4 Kilowatts We strongly encourage you to read and carefully follow the instruc tions laid out in this Installation Operation and Maintenance Manual and retain it for your future reference Pay special attention to all cautions warnings and ...

Page 4: ...l etc It is imperativethat controlcompartments burnersand circulatingair passagewaysof the fireplace are kept clean NOTICE Installations in Canada must conform to the local codes or in the absence of local codes to the current version of Natural Gas and Propane Installation Code CSA B149 Electrical Installations must conform to the local codes or in the absence of local codes to the current versio...

Page 5: ...Page 5 Hotshot Gas Fireplace Insert XG0511 150203 Installation Rating Plate Sample LBL1205 V6 1 Stand Pilot Screen DEC06 2014 Teklynx LabelView Demo ...

Page 6: ...ions Figure 1b Deluxe Arched Faceplate dimensions Figure 1c Standard Faceplate dimensions 27 3 4 705 25 634 21 3 8 544 10 3 4 272 20 507 23 5 8 600 14 1 8 357 27 3 4 705 16 1 4 411 15 7 8 405 20 1 4 513 21 1 2 545 14 5 8 371 16 1 8 410 11 280 Top View Front View Side View Note Images are shown without screens for clar ity purposes However your fireplace should not be operated without proper instal...

Page 7: ...ssure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Figure 3 Gas line location Note After the gas line is connected each appliance con nection val...

Page 8: ...ssible into the fireplace open ing Reach inside the opening above the Hotshot and insert the vent connector into the slot at the back of the fireplace Push the connector slide back as far as it will go to secure the chimney liner in position See figure 5b Centre the Hotshot in the fireplace opening and connect the gas line See Figure 3 To install the face plate and louvres see Installing Face Plat...

Page 9: ...ep 2 Install the Lower Louvre Assembly Position the Lower Louvre Assembly as shown in Figure 7 Line up the screw holes on the hinge with the pilot holes on the front of the fireplace and attach using three screws The lower louvres should rotate freely allowing easy access to the Hotshot control compartment Step 3 Install the Face Plate Trim To assemble the face plate trim slide the top end of the ...

Page 10: ...the top rail and one screw into each of the side rails as shown in figure 8b To remove face plate or face plate trims simply reverse above procedures Figure 8b Installing the trim Figure 9a Installing the upper louvres Figure 9b Installing the upper louvres Raise the Upper Louvre over the heat deflector ensuring the heat deflector is positioned between the bottom and middle louvre Figure 9c Comple...

Page 11: ...SA must be grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 NOTE If any of the original wire supplied with the appliance is replaced it must be replaced with the same type or its equivalent Removing and Installing the Screen and Door Removing the screen and door Figure 11a Removing the screw covers G H N Motor Fuse Heat sensor ...

Page 12: ...lass cleaner such as Kel Kem or White off NOTICE Installing the screen and door 1 Push the door up along the front of the firebox until the top edge of the door frame is underneath the Hotshot hood Line up the screw holes in the door with the corresponding holes on the front of the fireplace and attach with the four screws 2 Place screen over door and line up screw holes 3 Attach with four screws ...

Page 13: ...the fireplace If the flame appears satisfactory replace the glass door and door cover Figure 12a Positioning for the top logs C and D Installing the Log Set Installing the Logs The double burner Hotshot is supplied with a six 6 piece fibre log set 1 Remove the door cover and the glass door Back log Left log Right log Front log Center logs Figure 12b Proper placement top view Back log Front log res...

Page 14: ...turned from PILOT to OFF unless knob is pushed in slightly Do not force Standing Continuous Pilot Ignition SIT NOVA 820 with American Flame Electronic Ignition For Your Safety READ BEFORE LIGHTING If you cannot reach your gas supplier call the Fire Depart ment C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repa...

Page 15: ...terclockwise Figure 13 Hi Lo Adjustment on the Hotshot inset s gas valve Fan Adjustment Turn the fan On Off Speed Control to On The Fan will turn on and off automatically depending on the appliance s temperature Adjust the fans speed by turning clockwise or counterclockwise See figure 13 WARNING Avoid contact with hot fireplace glass while adjusting burner Fan On Off Speed Control On Off Switch Fi...

Page 16: ...ny part of the control system and any gas control which has been under water Cleaning WARNING Do not attempt to clean glass when hot Do not clean glass with abrasive materials as any glass etch ing may cause premature glass failure When the fireplace is first activated there may be some smoking and a visible film may be left on the glass This is a normal condition and is the result of burning of p...

Page 17: ...lly slide the burner tray forward to remove You may need to disconnect the gas line to remove the burner 6 Carefully put the burner tray to the side Take care to not damage the pilot wires Figure 14b Figure 14c 7 Remove 10 screws holding down the fan cover access plate Figure 14d 8 Disconnect fan power Remove the screws holding down fan bracket 9 Reverse steps to reinstall Make sure to replace the...

Page 18: ... Check wall switch for proper con nection 3 Check high limit switch If your fireplace still does not operate correctly consult your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts and optional such as trim finishes and the wireless infrared remote control are available from your local dealer or the manufacturer Replacement Parts Standing...

Page 19: ...be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under ...

Page 20: ...t of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve th...

Page 21: ...Page 21 Hotshot Gas Fireplace Insert XG0511 150203 Notes ...

Page 22: ...Ferndale Washington TF 1 800 789 6236 FX 1 866 3000 0927 Langley British Columbia TF 1 800 378 3115 FX 1 604 607 6462 XG0511 150203 Gas Fireplace Insert Hotshot ...

Reviews: