Summary of Contents for Hotshot DHS

Page 1: ...rature Strong magnetic field Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger of suffocation High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger...

Page 2: ...s 6 Clearances 7 Installing the Gasline 7 Chimney Liner Installation 8 Face Plate Trim and Louvres Face Plate Installation 9 Lower Louvre Assembly 9 Face Plate Trim 9 Upper Louvre Assembly 10 Wiring for the Air Circulating Fan 11 Removing and Installing the Screen Door 12 Installing the Logset 13 Operation 14 15 Maintenance 16 17 Warranty 19 Appendix 20 ...

Page 3: ...n a masonry fireplace equipped with a double burner glowing embers and a six piece log set The Hotshot DHS is rated for Natural Gas or Propane at 25 000 BTU H 7 4 Kilowatts We strongly encourage you to read and carefully follow the instruc tions laid out in this Installation Operation and Maintenance Manual and retain it for your future reference Pay special attention to all cautions warnings and ...

Page 4: ...l etc It is imperativethat controlcompartments burnersand circulatingair passagewaysof the fireplace are kept clean NOTICE Installations in Canada must conform to the local codes or in the absence of local codes to the current version of Natural Gas and Propane Installation Code CSA B149 Electrical Installations must conform to the local codes or in the absence of local codes to the current versio...

Page 5: ...Page 5 Hotshot Gas Fireplace Insert XG0511 150203 Installation Rating Plate Sample LBL1205 V6 1 Stand Pilot Screen DEC06 2014 Teklynx LabelView Demo ...

Page 6: ...ions Figure 1b Deluxe Arched Faceplate dimensions Figure 1c Standard Faceplate dimensions 27 3 4 705 25 634 21 3 8 544 10 3 4 272 20 507 23 5 8 600 14 1 8 357 27 3 4 705 16 1 4 411 15 7 8 405 20 1 4 513 21 1 2 545 14 5 8 371 16 1 8 410 11 280 Top View Front View Side View Note Images are shown without screens for clar ity purposes However your fireplace should not be operated without proper instal...

Page 7: ...ssure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Figure 3 Gas line location Note After the gas line is connected each appliance con nection val...

Page 8: ...ssible into the fireplace open ing Reach inside the opening above the Hotshot and insert the vent connector into the slot at the back of the fireplace Push the connector slide back as far as it will go to secure the chimney liner in position See figure 5b Centre the Hotshot in the fireplace opening and connect the gas line See Figure 3 To install the face plate and louvres see Installing Face Plat...

Page 9: ...ep 2 Install the Lower Louvre Assembly Position the Lower Louvre Assembly as shown in Figure 7 Line up the screw holes on the hinge with the pilot holes on the front of the fireplace and attach using three screws The lower louvres should rotate freely allowing easy access to the Hotshot control compartment Step 3 Install the Face Plate Trim To assemble the face plate trim slide the top end of the ...

Page 10: ...the top rail and one screw into each of the side rails as shown in figure 8b To remove face plate or face plate trims simply reverse above procedures Figure 8b Installing the trim Figure 9a Installing the upper louvres Figure 9b Installing the upper louvres Raise the Upper Louvre over the heat deflector ensuring the heat deflector is positioned between the bottom and middle louvre Figure 9c Comple...

Page 11: ...SA must be grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 NOTE If any of the original wire supplied with the appliance is replaced it must be replaced with the same type or its equivalent Removing and Installing the Screen and Door Removing the screen and door Figure 11a Removing the screw covers G H N Motor Fuse Heat sensor ...

Page 12: ...lass cleaner such as Kel Kem or White off NOTICE Installing the screen and door 1 Push the door up along the front of the firebox until the top edge of the door frame is underneath the Hotshot hood Line up the screw holes in the door with the corresponding holes on the front of the fireplace and attach with the four screws 2 Place screen over door and line up screw holes 3 Attach with four screws ...

Page 13: ...the fireplace If the flame appears satisfactory replace the glass door and door cover Figure 12a Positioning for the top logs C and D Installing the Log Set Installing the Logs The double burner Hotshot is supplied with a six 6 piece fibre log set 1 Remove the door cover and the glass door Back log Left log Right log Front log Center logs Figure 12b Proper placement top view Back log Front log res...

Page 14: ...turned from PILOT to OFF unless knob is pushed in slightly Do not force Standing Continuous Pilot Ignition SIT NOVA 820 with American Flame Electronic Ignition For Your Safety READ BEFORE LIGHTING If you cannot reach your gas supplier call the Fire Depart ment C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repa...

Page 15: ...terclockwise Figure 13 Hi Lo Adjustment on the Hotshot inset s gas valve Fan Adjustment Turn the fan On Off Speed Control to On The Fan will turn on and off automatically depending on the appliance s temperature Adjust the fans speed by turning clockwise or counterclockwise See figure 13 WARNING Avoid contact with hot fireplace glass while adjusting burner Fan On Off Speed Control On Off Switch Fi...

Page 16: ...ny part of the control system and any gas control which has been under water Cleaning WARNING Do not attempt to clean glass when hot Do not clean glass with abrasive materials as any glass etch ing may cause premature glass failure When the fireplace is first activated there may be some smoking and a visible film may be left on the glass This is a normal condition and is the result of burning of p...

Page 17: ...lly slide the burner tray forward to remove You may need to disconnect the gas line to remove the burner 6 Carefully put the burner tray to the side Take care to not damage the pilot wires Figure 14b Figure 14c 7 Remove 10 screws holding down the fan cover access plate Figure 14d 8 Disconnect fan power Remove the screws holding down fan bracket 9 Reverse steps to reinstall Make sure to replace the...

Page 18: ... Check wall switch for proper con nection 3 Check high limit switch If your fireplace still does not operate correctly consult your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts and optional such as trim finishes and the wireless infrared remote control are available from your local dealer or the manufacturer Replacement Parts Standing...

Page 19: ...be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under ...

Page 20: ...t of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve th...

Page 21: ...Page 21 Hotshot Gas Fireplace Insert XG0511 150203 Notes ...