General Information

 ................................................................. 2

Parts list

 .................................................................................... 2

Conversion

 

Before you begin ............................................................ 3

 

Front Burner ................................................................... 3

 

Rear Burner.................................................................... 3

 

Pilot Assembly ................................................................ 3

 

Main Gas Control Regulator........................................... 4

 

Check the Gas Pressure ................................................ 4

 

Adjusting the Pilot Burner............................................... 4

Operation

 ................................................................................... 5

General Information

This gas conversion kit contains the necessary components for field 
conversion of an approved Montigo fireplace from Natural Gas (NG) 
to Liquid Propane (LP). This kit  is approved for use with the top and 
rear vent versions of the following 

manufactured (mobile) home

 

models:

 

DFSP 

 

DXFS 

 

DFSP-MH 

 

DXFS-MH

A manufactured (mobile) home OEM installation in the 

United States 

must conform with the Manufactured Home Construction and Safety 
Standard, 

Title 24 CFR, Part 3280

, or, when such a standard is not 

applicable, the Standard for Manufactured Home Installations, 

ANSI 

/ NCSBCS A225.1

. In 

Canada

, the installation must conform to the 

Standard for Gas Equipped Recreational Vehicles and Mobile Hous-
ing, CSA Z240.4.
The installation of this unit must also conform with local codes or, in 
the absence of local codes, with the 

American

 National Fuel Gas 

WARNING!

This conversion kit shall be installed by a qualified service 

agency in accordance with the manufacturer's instructions 

and all applicable codes and requirements of the authority 

having jurisdiction. If the information in these instructions 

is not followed exactly, a fire, explosion or production of 

carbon monoxide may result causing property damage, 

personal injury or loss of life. The qualified service agency 

is responsible for the proper installation of this kit. The 

installation is not proper and complete until the operation 

of the converted appliance is checked as specified in the 

manufacturer's instructions supplied with this kit.

Parts List

Quantity 

Description

 

Pilot orifice

 

Rear burner orifice

 

Front burner orifice

 

Gas control valve regulator assembly

 

Label for rating plate indicating conversion

 

Label for gas control valve indicating conversion

 

Rear Burner

 

Front Burner

Summary of Contents for  DFSP

Page 1: ...gas indicated on the rating plate A conversion kit is supplied with the appliance Warning If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What To Do If You Smell Gas Do not try to li...

Page 2: ...tandard for Gas Equipped Recreational Vehicles and Mobile Hous ing CSA Z240 4 The installation of this unit must also conform with local codes or in the absence of local codes with the American National Fuel Gas WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority h...

Page 3: ...r Burner 6 Remove the clip that secures the rear burner to the firebox Slide the rear burner tube off the orifice on the right hand side Unscrew the old orifice from the orifice holder and replace it with the new orifice from this kit marked R rear Tighten the new orifice until it is snug to prevent any leaks Pilot Assembly 7 While you have the rear burner removed unscrew the pilot hood counter cl...

Page 4: ...ssure readings are not within the limits set out contact the factory If the pressure readings are correct ensure that both test con nection screws are tightened securely to prevent a gas leak Pilot Burner Adjustment 1 Locate Pilot Adjustment Screw See figure 6 2 Adjust pilot screw to provide properly sized flame as shown in fig ure 7 To increasethe flame turn the screw counterclockwise To decrease...

Page 5: ...ce 3 Push in gas control knob slightly and turn clockwise to Off Do not force 1 Turn off remote switch 2 Locate the gas control valve on the back left side of the unit 1 STOP Read the safety information above on this label 2 Locate the gas control valve on the back left side of the unit 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas in...

Page 6: ...Canadian Heating Products Inc Surrey BC V3W 2V6 Montigo Del Ray Corp Ferndale WA 98248 XG0667 Rev 00 07 02 ...

Reviews: