background image

P/N XG0667

Page

Gas Conversion Kit for DXFS/DFSP-MH models

Main Gas Control Regulator Screw:
11.

  The stove models use the Honeywell Hi/Lo gas control valve, 

which has a removable regulator screw. The kit will include a 
new regulator screw, the red screw is for Propane (LP) and the 
blue screw is for Natural Gas (NG). It is located  in the middle of 
the hi/lo knob, replace it, and install the new regulator screw.

Gas Conversion Instructions

Checking the Gas Pressure

To check the Inlet and Manifold gas pressures, a Water Column Pres-
sure Gauge with 5/16" dia. tubing can be used. Make sure the gas 
shut-off valve is closed, then attach the gauge to the Manifold Pres-
sure Test Connection by loosening the screw shown in Figure 6. The 
tubing must be tight in the connection to prevent gas leaks. Measure 
the Manifold Pressure and compare the value against the chart below.
Turn off the fireplace and close the shutoff valve. Remove the test 

Figure 6. 

Honeywell VS8520E 

gas valve

.

 

Natural Gas 

Liquid Propane

Manifold Pressure (min.) 

3.5" W.C. 

10" W.C.

Inlet Pressure (min.- max.)  5.5" - 14" W.C. 

11" - 14" W.C.

" W.C. = inches water column

gauge. Re-tighten the test connection screw to prevent gas leakage.
Repeat the procedure for the Inlet Pressure.
If the pressure readings are not within the limits set out, contact the 
factory. If the pressure readings are correct, ensure that both test con-
nection screws are tightened securely, to prevent a gas leak.

Pilot  Burner Adjustment

1.

  Locate Pilot Adjustment Screw. 

(See figure 6)

2.

  Adjust pilot screw to provide properly sized flame as shown in 

 fig-

ure 7). 

To increasethe flame, turn the screw counterclockwise. To 

decrease the flame, turn it clockwise. The flame should impinge 
on the thermocouple and thermopile.

3.

  After installing or servicing, leak test using a soap solution with 

main burner turned on. Coat pipe and tubing joints, gasket etc. 
with soap solution. Bubbles indicate leaks. Tighten any areas 
where the bubbles appear until the bubbling stops completely.

Figure 7. Pilot Burner

 

12.

  The label (part no. XL0201) indicating that

 the fireplace 

has been 

converted for use with a different gas  must be placed on the 
fireplace rating plate over top of the existing fuel type chart.

 

The label (part no. XL0200) indicating 

who

 converted the ap-

pliance must be filled out and placed on the base pan, directly 
under the gas valve.

 

Also place the label indicating that the 

control valve 

has been 

converted for use with a different gas.

Figure 5.  Converting the Honeywell VS8520E regulator screw.

HI

LO

Gas control knob

(shown in “Off” position”)

Hi/Lo control knob

Regulator Screw

HI

LO

Gas control knob

(shown in “Off” position”)

Hi/Lo control knob

Pilot Adjustment

Summary of Contents for  DFSP

Page 1: ...gas indicated on the rating plate A conversion kit is supplied with the appliance Warning If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What To Do If You Smell Gas Do not try to li...

Page 2: ...tandard for Gas Equipped Recreational Vehicles and Mobile Hous ing CSA Z240 4 The installation of this unit must also conform with local codes or in the absence of local codes with the American National Fuel Gas WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority h...

Page 3: ...r Burner 6 Remove the clip that secures the rear burner to the firebox Slide the rear burner tube off the orifice on the right hand side Unscrew the old orifice from the orifice holder and replace it with the new orifice from this kit marked R rear Tighten the new orifice until it is snug to prevent any leaks Pilot Assembly 7 While you have the rear burner removed unscrew the pilot hood counter cl...

Page 4: ...ssure readings are not within the limits set out contact the factory If the pressure readings are correct ensure that both test con nection screws are tightened securely to prevent a gas leak Pilot Burner Adjustment 1 Locate Pilot Adjustment Screw See figure 6 2 Adjust pilot screw to provide properly sized flame as shown in fig ure 7 To increasethe flame turn the screw counterclockwise To decrease...

Page 5: ...ce 3 Push in gas control knob slightly and turn clockwise to Off Do not force 1 Turn off remote switch 2 Locate the gas control valve on the back left side of the unit 1 STOP Read the safety information above on this label 2 Locate the gas control valve on the back left side of the unit 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas in...

Page 6: ...Canadian Heating Products Inc Surrey BC V3W 2V6 Montigo Del Ray Corp Ferndale WA 98248 XG0667 Rev 00 07 02 ...