background image

Page

P/N XG0667

Gas Conversion Kit for DXFS/DFSP-MH models

Operating Instructions

WARNING:

 

If you do not follow these instructions exactly, a fire or explosion 

may result causing property damage, personal injury or loss of life.

  If you cannot reach your gas supplier, call the Fire De-

partment.

C.

  Use only your hand to push in or turn the gas control knob. 

Never use tools. If  the knob will not push in or turn by hand, 
don't try to repair it, call a qualified service technician. Force 
or attempt to repair may result in a fire or explosion.

D.

  Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 
appliance and to replace any part of the control system, and 
any gas control which has been under water.

A. 

This appliance has a pilot which must be lighted by hand. 
When lighting the pilot, follow these instructions exactly.

B.  BEFORE LIGHTING

 smell all around the appliance area for 

gas.  Be sure to smell next to the floor because some gas is 
heavier than air and will settle on the floor.

 

What To Do If You Smell Gas:

  Do not try to light any appliance.

  Do not touch any electrical switch; do not use any phone 

in your building.

  Immediately call your gas supplier from a neighbour's 

phone. Follow the gas supplier's instructions.

To Turn Off Gas To Appliance:

3.  Push in gas control knob slightly and turn  

  clockwise 

to "Off".  Do not force.

1.  Turn off remote switch.
2.  Locate the gas control valve on the back left side of the unit

1.

 

STOP!

 

 

Read the safety information above on this label.

2.

  Locate the gas control valve on the back left side of the unit.

3.

  Push in gas control knob and turn clockwise 

  to "OFF."

4.

  Wait five (5) minutes to clear out any gas. Smell for gas, 

including near the floor. If you then smell gas, 

STOP!

 Follow 

"B" in the safety information above on this label. If you don't 
smell gas, go to the next step.

5.

  Locate pilot burner 

(See illustration at right.)

 and follow 

steps below.

6.

  Turn knob on gas control counterclockwise  

  to "PI-

LOT."

7.

  Push in gas control knob completely and hold. Light with 

Piezo Igniter button. Continue to hold the control knob in for 
about (1) minute after the pilot is lit. Release the knob and it 
will pop back up. Pilot should remain lit. If it goes out repeat 
steps 3 through 8.

  If knob does not pop up when released. Stop and im-

mediately call your service technician or gas supplier.

  If the pilot will not stay lit after several tries, turn the gas 

control knob to "OFF" and call your 
service technician or gas 
supplier.

8.

  Push in gas control knob and 

turn counterclockwise  

  to 

"ON."

9.

  Turn on remote switch to ignite fire.

Lighting  Instructions:

For Your Safety - READ BEFORE LIGHTING:

NOTE:  Gas control knob cannot be turned from  

"PILOT" to "OFF" unless knob is pushed 

 in slightly.  Do not force.

HI

LO

Gas control knob

(shown in “Off” position”)

Hi/Lo control knob

Summary of Contents for  DFSP

Page 1: ...gas indicated on the rating plate A conversion kit is supplied with the appliance Warning If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What To Do If You Smell Gas Do not try to li...

Page 2: ...tandard for Gas Equipped Recreational Vehicles and Mobile Hous ing CSA Z240 4 The installation of this unit must also conform with local codes or in the absence of local codes with the American National Fuel Gas WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority h...

Page 3: ...r Burner 6 Remove the clip that secures the rear burner to the firebox Slide the rear burner tube off the orifice on the right hand side Unscrew the old orifice from the orifice holder and replace it with the new orifice from this kit marked R rear Tighten the new orifice until it is snug to prevent any leaks Pilot Assembly 7 While you have the rear burner removed unscrew the pilot hood counter cl...

Page 4: ...ssure readings are not within the limits set out contact the factory If the pressure readings are correct ensure that both test con nection screws are tightened securely to prevent a gas leak Pilot Burner Adjustment 1 Locate Pilot Adjustment Screw See figure 6 2 Adjust pilot screw to provide properly sized flame as shown in fig ure 7 To increasethe flame turn the screw counterclockwise To decrease...

Page 5: ...ce 3 Push in gas control knob slightly and turn clockwise to Off Do not force 1 Turn off remote switch 2 Locate the gas control valve on the back left side of the unit 1 STOP Read the safety information above on this label 2 Locate the gas control valve on the back left side of the unit 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas in...

Page 6: ...Canadian Heating Products Inc Surrey BC V3W 2V6 Montigo Del Ray Corp Ferndale WA 98248 XG0667 Rev 00 07 02 ...