background image

 

Check local codes and 

read  all  instructions 

prior to installation.

 

Leave this manual with 

the owner.

For Mobile /Manufac-

tured Home approved 

models:

 

DXFS

 

DFSP

 

DXFS-MH

 

DFSP-MH

Gas Conver-
sion Instruc-
tions

This appliance may be installed as an OEM installation in a 

manufactured 

(mobile) home

 and must be installed in accordance with the manufacturer's 

instructions and the manufactured home construction and safety standard, 

Title 24 CFR, Part 3280

 or Standard for Installation in 

Mobile Homes, CAN / 

CSA Z240 MH

.

This appliance is only for use with the type(s) of gas indicated on the rating 
plate. A conversion kit is supplied with the appliance.

Warning:

 

If the information in these instructions is not followed 

exactly, a fire or explosion may result causing property damage, 

personal injury or loss of life.

 

Do not store or use gasoline or other flammable vapors and liquids in the 
vicinity of this or any other appliance.

 

What To Do If  You Smell Gas:

•   Do not try to light any appliance.

•   Do not touch any electrical switch;  do not use any phone in your building.

•   Immediately call your gas supplier from a neighbor's phone.  Follow the gas 

supplier's instructions.

•   If you cannot reach your gas supplier, call the fire department.

 

Installation and service must be performed by a qualified installer, service agency or 
the gas supplier.

Summary of Contents for  DFSP

Page 1: ...gas indicated on the rating plate A conversion kit is supplied with the appliance Warning If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What To Do If You Smell Gas Do not try to li...

Page 2: ...tandard for Gas Equipped Recreational Vehicles and Mobile Hous ing CSA Z240 4 The installation of this unit must also conform with local codes or in the absence of local codes with the American National Fuel Gas WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority h...

Page 3: ...r Burner 6 Remove the clip that secures the rear burner to the firebox Slide the rear burner tube off the orifice on the right hand side Unscrew the old orifice from the orifice holder and replace it with the new orifice from this kit marked R rear Tighten the new orifice until it is snug to prevent any leaks Pilot Assembly 7 While you have the rear burner removed unscrew the pilot hood counter cl...

Page 4: ...ssure readings are not within the limits set out contact the factory If the pressure readings are correct ensure that both test con nection screws are tightened securely to prevent a gas leak Pilot Burner Adjustment 1 Locate Pilot Adjustment Screw See figure 6 2 Adjust pilot screw to provide properly sized flame as shown in fig ure 7 To increasethe flame turn the screw counterclockwise To decrease...

Page 5: ...ce 3 Push in gas control knob slightly and turn clockwise to Off Do not force 1 Turn off remote switch 2 Locate the gas control valve on the back left side of the unit 1 STOP Read the safety information above on this label 2 Locate the gas control valve on the back left side of the unit 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas in...

Page 6: ...Canadian Heating Products Inc Surrey BC V3W 2V6 Montigo Del Ray Corp Ferndale WA 98248 XG0667 Rev 00 07 02 ...