XG0221
28
Installation
This conversion kit shall be installed by a qualified gas fitter in
accordance with the manufacturer’s instructions and all applicable
codes and requirements of the Authority Having Jurisdiction. If
the information in these instructions is not followed exactly, a fire,
explosion or production of carbon monoxide may result causing
property damage, personal injury or loss of life. The qualified service
agency is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of the
converted appliance is checked as specified in the manufacturer’s
instructions supplied with the kit.
Figure 13. Removal of burner strip
Figure 13.b Loosening the venturi
Figure 13.c
Removing the orifice
Figure 13.d Removing the spring clip
3. Loosen the a screw holding the venturi opening. Slide the
venturi cover over so the opening is at the maximum width.
Re-tighten screw.
1. Shut off gas supply. Follow Burner tray removal instructions.
Continue with the Propane Conversion instructions.
5. Use screwdriver to carefully detach spring clip from the pilot
hood. (Spring clip will be reused)
4. Use 3/8" Socket Driver to loosen off the NG gas orifice, replace
with Propane orifice as included in package.
(46DMS for D6315STLI-2, 49DMS for DL6315STLI-2)
Propane Conversion
Tools required
1). Torx T20 Screw Driver Bit
2). 3/8" Socket Driver
3). 5/32" Allen Key
4). Needle Nose Pliers or
Small Flat Head Screw
Driver
Parts included
1). Propane burner orifice
2). Propane pilot orifice
3). Propane valve control
(with mounting screws)
4). Valve conversion label
5). Conversion plate label
6). Conversion technician
identifying label
To convert the Distinction
from Natural Gas to Propane,
install the GCA008 conversion
kit for DL units, and the
GCA009 for D units. The unit
must be disconnected from
any gas supply, disconnected
from any electrical supply and
batteries and removed from
any installation cavity.
FOR NATURAL GAS BURNER
REPLACEMENT, VENTURI
SETTING IS 5/32.
For input rating, manifold
pressure and orifice size,
refer to sample rating plate
on page 6
2. Loosen the 4 screws securing the burner strip to the stands.
The gas supply shall be shut off prior to disconnecting the electrical
power, before proceeding with the conversion.