XG0221
23
Installation
Connection and installation of the vent
components should adhere to the following
guidelines:
Section 3-3-2: Venting Components
The following components and associated Montigo part numbers for
installation of a roof or wall mounted termination. Use of non-Montigo
approved parts will VOID the warranty and may impede operation of
the fireplace.
•
Use any combination of rigid and flex pipe as required and in any
orientation (Male connectors can face in any direction).
•
Flex sections may be stretched up to 50% of their total length (e.g.
a 24” section maybe stretched to 36”).
• Connect all vent sections using a minimum of three sheet metal
screws on the outer pipe flue.
•
Ensure the pipe ends male to female slide in a minimum of 1 1/2”
of overlap.
•
Ensure all horizontal runs are supported with a minimum of 3
supports per 10’ of venting.
•
When hanging/supporting venting, ensure that 1” clearance is
maintained on sides and bottom of vent runs and 2” above horizontal
vent runs to any combustible material.
• Rigid pipe may be cut less than half way from the
FEMALE END ONLY.
•
Flex pipe cannot be cut
•
Ensure when cutting sections of rigid pipe to maintain integrity of
internal supports.
•
For flex venting, place the springs supplied with the pipe kit, between
the outer and inner pipes to keep the pipes separate and avoid any
possible hot spots.
•
Montigo recommends the use of a flex section for the final pipe
connected directly to the fireplace offering greater flexibility of
installation and absorption of movement.
•
Firestops must be installed as required by National & local codes.
IMPORTANT:
Please Refer to your Building Envelope Engineer
or Waterproofing Consultant for a review of ALL
penetrations through exterior walls or the roof.
A - Termination
PTO4 (3" Length)
PTO4F (3" Length)
PVTK1SS
B - Frame Kits
MSR (Stucco Frame)
MOSR (Stucco Frame)
BSR-4 (4" Brick Frame)
BSR-6 (6" Brick Frame)
C - Flex Sections
PFL - 1 (12" f/f Section)
PFL - 18 (18" f/f Section)
PFL - 2 (24" f/f Section)
PFL - 3 (36" f/f Section)
PFL - 4 (48" f/f Section)
PFL - 6 (72" f/f Section)
D - Rigid Pipe
PEXT - 1 (12" f/m Section)
PEXT - 2 (24" f/m Section)
PEXT - 3 (36" f/m Section)
PEXT - 4 (48" f/m Section)
PEXT - 6 (72" f/m Section)
E - Rigid Pipe Extension
PXT - 5 (5" f/f Section)
PXT - 12 (12" f/f Section)
PXT - 20 (20" f/f Section)
F - Elbows
PEL-90MM (m/m 90º Elbow)
PEL-90FF ( f/f 90º Elbow)
PEL-90FM ( f/m 90º Elbow)
PEL-45FM ( f/m 45º Elbow)
G - Wall Penetration Kit
PFVK01F
H - Support Ring & Plate
PSPXT-8
I - Firestop
FS-8
J - Roof Flashing
PRF-7 (1/12 - 7/12 pt.)
PRF-12 (7/12 - 12/12 pt.)
K - Heat Shield
RHS101
L - Heat Guard
MTKOG