XG0221
17
Installation
Vertical Termination - 2 Elbows
Vertical Termination
Vertical Termination - 2 Elbows
Vertical Termination
Figure 8. Vertical Termination
Figure 8.b Vertical Termination - 2 Elbows
*Restrictor may be required
If the vent rise is over 8ft straight vertical, a restrictor must be installed.
We recommend using the 1.75” wide restrictor. If 1.75'' is too restrictive,
a 1.5'' and 1'' restrictor is also supplied.
NOTE:
If using a restrictor, use an IR gun to measure the glass
temperature after 1 hour of running, and ensure the glass temperature
does not exceed 470°F and ensure that none of the media and no part
of the door has discoloured.
*Minimum 24'' from top of unit before attaching an elbow
V1
V1
H1
V2
Section 3-3-1: Venting Layouts
D6315, D6315ST, DL6315, DL6315ST
Vertical Minimum
Vertical Maximum
3 FT
32 FT
D6315ST, DL6315ST
Vertical
Minimum
V1+V2
Horizontal
Maximum
H1
2 FT
3 FT
3 FT
6 FT
4 FT
9 FT
5 FT
12 FT
6 FT
15 FT
7 FT
18 FT
8 FT
21 FT
D6315, DL6315
Vertical
Minimum
V1+V2
Horizontal
Maximum
H1
2 FT
1 FT
3 FT
4 FT
4 FT
7.5 FT
5 FT
11 FT
6 FT
14 FT
7 FT
17.5 FT
8 FT
21 FT