XG0222
25
Installation
Figure 13.e
Removing the pilot hood, orifice
Figure 13.f
Insert propane orifice, reassemble burner
Figure 13.g
Adjust pilot size
Figure 13.h
Adjust pressure ports
Figure 13.i
Label reverse rating plate
Figure 13.j
Conversion label on rating plate label
Figure 13.k
Conversion label on valve
11. Fill out required information on Propane conversion gas fitter
sign off label, attach to reverse side of rating plate. Attach
Rating plate conversion label to rating plate label. Place Valve
conversion label on valve face.
8. The pilot size can be adjusted using a flathead screwdriver to
adjust “pilADJ” screw shown
9. The manifold and inlet pressure can be verified by using a
manometer and a 1/8” rubber hose attached to the valve
ports shown here (top is manifold, bottom is inlet)
10. Use a soap-based leak testing solution on the valve regulator
while the unit is operating to check for any leaks
7. Insert Propane pilot orifice. Reassemble burner assembly.
6. Remove pilot hood, then use allen key to remove pilot orifice.