Page 17
BF-Series-ST Gas Fireplace
Part No. XG0711 - 022410
f i r e f e a t u r e
Operation - Model BF-ST-A
For Your Safety - READ BEFORE LIGHTING:
To Turn Off Gas To Appliance:
Lighting Instructions:
What To Do If You Smell Gas:
■
Do not try to light any appliance.
■
Do not touch any electrical switch; do not use any phone
in your building.
■
Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
■
If you cannot reach your gas supplier, call the Fire
Department.
A.
This appliance is equipped with an ignition system that allows
for both continuous pilot operation as well as an electronic
ignition that lights the pilot burner automatically.
Do not attempt
to light the pilot by hand.
B. BEFORE LIGHTING
smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
1.
Turn off remote switch.
2.
Remove the lower Horizontal access panel..
3.
Turn the switch on the Control Module to "Continuous Pilot
Off".
4.
Replace the lower Horizontal access panel.
1.
STOP!
Read the safety information above on this label.
2.
Remove the lower Horizontal access panel..
3.
If the switch on the control module is set to "Continuous Pilot
Off" then the pilot will light when the appliance is turned on
by the remote switch. When switched to "Continuous Pilot
On" then the control module will attempt to light the pilot until
it detects that the pilot has been successfully lit.
4.
With the control module set to "Continuous Pilot Off" wait 5
minutes to clear out any gas. If you smell gas,
STOP!
Follow
"B" in the safety information above on this label. If you don't
smell gas, go to the next step.
5.
Turn switch on the control module to "Continuous
Pilot On" This will initiate the lighting of the pilot.
NOTE:
This unit is equipped with an ignition system that lights
the pilot burner automatically.
Do not attempt to light the
pilot by hand.
6.
Turn on wall switch.
7.
Replace the lower Horizontal access panel.
8.
If the fireplace does not operate, follow the instructions "To
Turn Off Gas To Appliance" and call your service technician
or gas supplier.
9.
If you wish to operate the Fireplace without the Continous Pilot
simply turn the switch on the control module to "Continuous
Pilot Off" and follow instructions 6-8.
with American Flame Electronic Ignition
WARNING:
If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
ADJ.
AUX
Learn
Remote/Off
Continuous
Pilot Off/On
S
I
IPI
POWER
6VAC 200mA
AC ADAPTOR
Wall Switch (SWI)
Brown
Brown
Black
White
Green
White
Orange
Pilot
Main
Manual
Hi/Lo
Main Gas Input
Main Gas Output
White (Sensor)
Orange (Igniter)
Control
Module
Emergency
Battery
Power
(4 x AA)
Pilot Assembly
Red
Black
Red
Black
Optio
nal