I-Series Indoor Gas Fireplace
Installation
Gas line connection
The 34FID-S Insert is supplied with a flexible gas line that uses
a ½” female flair to connect to your service. The flexible gas
line is a one time connection. If you ever have to break the
connection, you must replace the flexible gas line. There is
also a safety shutoff valve that is built in and operated when
needed used the door removal tool. Depending on your local
gas codes, you may need to provide an additional gas shut
off valve or even hard pipe the unit. In the event that you
need to hard pipe the gas supply, a union will be required.
Figure 24 Sec.6
Control valve and gas flex line shown.
Emergency Shut-off Valve
This appliance is equipped with a shut-off valve for use incase
of emergency. It is located on top of the appliance gas valve
and can be accessed and operated through the front of the
fireplace using the door tool. Appliance is shipped from the
manufacturer with the emergency shut-off valve in the closed
position.
Figure 25 Sec.6
Inserting door tool through the front of the fireplace
Hook the door tool into the arm of the emergency shut-off valve.
Pull the door tool towards you to open the valve and push it away
from you to close the valve.
Figure 26 Sec.6
Emergency shut-off valve shown in closed position.
Hook Door Tool Here
Pull This Direction
To Open
WARNING
When installing the fireplace - gas lines, fittings, accesso-
ries or any other objects cannot impede the proper
movement of the door buckles.