Page 47
XG00516-060614
I-Series Indoor Gas Fireplace
Operation
Mode Key
Initializing the System for the first time
1. Set master override switch to off position.
2. Install four (4) AA batteries into the battery holder, see page
27.
3. Install three (3) AAA batteries in the back of the remote
control, see
figure 28
.
Note the polarity of batteries and install them as indicated by
the silk screen (+/-) on the holder.
4. Connect AC Power (115 volts, 60 Hz) to fireplace.
Operating the System for the first time
5. Press SW1 button on the control module. The control module
will beep three (3) times and amber LED, see
figure 26,
is
illuminated to indicate that the IFC is ready to synchronize
with a remote control within 10 sec. Push the ON button. The
control module will "beep" four (4) times to indicate transmitter's
command is accepted.
The System is now initialized.
Figure 11 Sec.10
Remote control battery compartment.
Temperature indication Display
With the system in the "Off" position, press the Thermostat Key
and the Mode Key at the same time. Look at the LCD screen
on the Remote Control to verify that a C or F is visible to the
right of the Room Temperature display, see
figure 29
.
Turn On the Fireplace
With the system Off, turn the master override switch to on and
press the On/Off Key on the Remote Control. The Remote
Control display will show some other active Icons on the
screen. At the same time the Control Module will activate the
fireplace. A single "beep" from the Control Module will confirm
reception of the command.
Figure 12 Sec.10
Remote Control display in Fahrenheit & Celsius.
Turn Off the Fireplace
With the system On, press the On/Off Key on the Remote
Control. The Remote Control LCD display will only show the
room temperature, see
figure 30
. At the same time the Control
Module will turn off the fireplace. A single "beep" from the
Receiver confirms reception of the command.
Figure 13 Sec.10
Remote Control display.
Battery operated device.
Read the battery instructions before installing them
.
WARNING
into the system. Do not expose any battery, or its holder, or a device in which