background image

   7

6

8

Wards.com      

1

888

557

3848

Wards.com      

Installation 

(cont’d)

Installation 

(cont’d)

Remove air conditioning unit and accessories from box. Save box to use for storage 

of unit during the winter or when not in use for long periods of time. 

1. Upper Guide

Secure the Upper Guide (Item E) to the top of the air conditioner using the 3 screws 

(Item A) provided. 

Item

Name of Part

Qty.

A

SCREW (ST4X10FT)

3

B

SCREW (ST4X16FT)

5

C

GUIDE PANEL (LEFT)

1

D

GUIDE PANEL (RIGHT)

1

E

UPPER GUIDE

1

F

FOAM STRIP (Adhesive back)

1

G

FOAM STRIP (Non-adhesive back)

1

Tools Required for Installation

•  Gloves

•  Cross-Tip screwdriver

•  Pliers

•  3/8-inch adjustable wrench

•  1/4-inch hex socket and rachet

•  Tape measure

•  Drill (if pilot holes are needed) with 1/4-inch drill bit

2. Guide Panels

Extend the curtains in the left and right guide panels (Items C & D). Fit them into 

the T-shaped groove on each side of the unit, and slide into place.

3. Foam Strip

Cut the adhesive-backed foam strip (Item F) to the width of the window. Remove 

backing from foam and attach strip to the underside of the window. 

4. Window Center

With the window open, find and mark the center line of the inner sill. 

CAUTION: Hold unit firmly until window sash is lowered to top channel behind the 

upper guide. Personal injury or property damage may result if the air conditioner 

falls from the window.

5. Install Air Conditioner in Window

Carefully fit the unit into the open window, lining up the center of the unit with the 

center line on the sill. 

Firmly hold on to unit while lowering the window sash down 

behind the upper guide. 

Extend side curtains to fill the open window.

Summary of Contents for 718909

Page 1: ...0W Wards com 1 888 557 3848 MODEL MW5000 Montgomery Ward Customer Service 1112 7th Avenue Monroe WI 53566 8 00 am to Midnight Monday through Friday Wards com 1 888 557 3848 Window AC 5000BTU Outside Back Cover Outside Front Cover Energy Saving Mode ...

Page 2: ...ng local ordinances 7 Use the plug to disconnect from electrical outlet never pull out by the cord 8 Do not modify or alter the plug or power cord 9 Turn power OFF before removing plug from outlet 10 Never operate the appliance or remove the plug with wet hands 11 Do not use an extension cord with this appliance 12 Do not operate any appliance with a damaged cord or plug or after the appliance mal...

Page 3: ...lectrical shock serious injury or death Important Safeguards cont d ing filter 20 Before cleaning turn power OFF and unplug from electrical outlet 21 Do not insert body parts or tools into the inlet or outlet grills during operation 22 Do not ingest water drained from air conditioner 23 Do not store flammable or combustible liquids by unit 24 Do not step or sit on air conditioner 25 Do not store a...

Page 4: ...art Qty A SCREW ST4X10FT 3 B SCREW ST4X16FT 5 C GUIDE PANEL LEFT 1 D GUIDE PANEL RIGHT 1 E UPPER GUIDE 1 F FOAM STRIP Adhesive back 1 G FOAM STRIP Non adhesive back 1 Tools Required for Installation Gloves Cross Tip screwdriver Pliers 3 8 inch adjustable wrench 1 4 inch hex socket and rachet Tape measure Drill if pilot holes are needed with 1 4 inch drill bit 2 Guide Panels Extend the curtains in ...

Page 5: ... the upper guide Personal injury or property damage may result if the air conditioner falls from the window 5 Install Air Conditioner in Window Carefully fit the unit into the open window lining up the center of the unit with the center line on the sill Firmly hold on to unit while lowering the window sash down behind the upper guide Extend side curtains to fill the open window If AC is blocked by...

Page 6: ... down arrow to decrease the temperature which is displayed on the control panel Every press of the but ton will increase or decrease the temperature by 1 F The range of settings is 88 F to 61 F Temperature controls only work in cooling mode Timer Set Use this button to designate the number of hours up to 24 the unit should run continuously until automatically shutting down or the number of hours u...

Page 7: ...t 2 Wash filter under warm tap water Do not soak or use any detergent Shake off water before replacing filter Air Conditioner Cleaning To clean the front grill and air inlet wipe with a soft cloth dampened with mild soap or detergent The cabinet may also be washed with mild soap or detergent and lukewarm water To keep your air conditioner running at peak efficiency the condenser coils on the back ...

Page 8: ...rm Lower the temperature Room temperature is below 61 F Cooling will not occur until room temperature is above 61 F Temperature sensor tube is touching the evaporator coil Remove front grill and move sensor tube back into the holding clip AC is cooling but room is warm and ice formed behind air inlet grill Outdoor temperature is below 70 F To defrost coil set the AC to fan mode Air filter may be d...

Page 9: ...ude your order number and reason for return We recommend keeping the receipt for 4 weeks Returns Montgomery Ward Inc warrants this product to be free from defects in material and workmanship for one year from provable date of purchase Within this warranty period Montgomery Ward will repair or replace at its option defective parts of this product at no charge provided the product is returned freigh...

Reviews: