19
www.montanarigiulio.com
MGX19
ENGLISH
!
!
Brake disc closed
Condition
contact
Brake disc free
Condition
contact
Disconnected
Connected
Connected
Disconnected
BLACK
COM.
BLUE
N.O.
BLACK
COM.
GREY
N.C.
COM.
N.C.
BLACK
COM.
BLUE
N.O.
Fig. 10
Shielding cable
(Grey)
Grounding
(Yellow green)
Power cables for
the U-V-W phases
(1 - 2 - 3)
• The power cable must be routed separately from the other cables.
• The motor power cable is shielded and the shield must be grounded.
• The encoder cable must be routed away from the motor power cable to avoid
electrical interference.
• The brake system has a power cable and another cable for the microswitch
contacts. (Figure no. 11). All electrical data are listed on the label of the brake
system. The microswitch has two contacts: one open and one closed. (Fig. 12).
• These contacts indicate the brake condition (tab. 5).
Tab. 5
Cables for PTC (T5 - T6)
Power cable and PTC.
6.4 Electrical installation - Connections
The gearless machine is supplied with:
• power cable for the power supply of the motor [1 - 2 - 3, Ground, SC] and of
the PTC [T5-T6] (Fig. 10).
BLACK
GREY