9
SERVICE
WHEN SERVICE IS NEEDED, CONTACT A LOCAL SERVICE COMPANY, DEALER, OR THE
FACTORY TO PERFORM MECHANICAL MAINTENANCE AND REPAIRS. THESE
INSTRUCTIONS ARE INTENDED FOR USE BY COMPETENT SERVICE PERSONNEL.
Gas Pressure Regulator
Pilot Service
If pilot flame burns yellow, clean pilot to ensure a steady blue flame. This can be cleaned by
washing in a solvent and/or blowing out with air.
Adjustment of pilot valve is located on the manifold behind the control panel. Clockwise is ―OFF‖,
counterclockwise is ―ON‖. Flame height should be approximately 1/2‖.
Burner Valve
If burner valve becomes too difficult to turn:
1. Turn off gas to the unit.
2. Remove knobs and control panel.
3. Lift burner out.
4. Loosen nut on front of valve and remove stem.
5. Lubricate the valve stem with high temperature grease.
6. Reassemble.
Upon completion, turn gas on and check for leaks. The valve should be turned on and off several
times to seat correctly.
Burner Box
For removal of burner box, contact the factory.
CAUTION!
TURN OFF GAS AT MANUAL SHUT OFF VALVE NEXT TO THE APPLIANCE BEFORE
ATTEMPTING TO LOOSEN ANY GAS CONNECTIONS.
WARNING!
NO UNTRAINED PERSON SHOULD ATTEMPT TO MAINTAIN OR SERVICE THE GAS
PRESSURE REGULATOR.