3
INSTALLATION
The MONTAGUE gas broilers are produced with the best possible materials and workmanship.
PROPER INSTALLATION IS ESSENTIAL FOR SAFE AND EFFICIENT TROUBLE-FREE
OPERATION.
Qualified installation personnel are individuals, a firm, corporation, or company which either in
person or through a representative are engaged in, and are responsible for:
A. The installation or replacement of gas piping or the connection, installation, repair or servic-
ing of equipment, who is experienced in such work, familiar with all precautions required, and
has complied with all requirements of state or local authorities having jurisdiction. Reference:
National Fuel Gas Code Z223.1, 1988, Sec. 1.4.
B. The installation of electrical wiring from the electric meter, main control box, or service outlet
to the electric appliance. Qualified installation personnel must be experienced in such work
be familiar with all precautions required and have complied with all requirements of state and
local authorities having jurisdiction. Reference: National Electric Code, N.F.P.A. No. 70,
1988.
Ventilating Hood
The broiler must be installed under a properly designed hood. The hood should extend at
least 6” beyond all sides of the unit. The hood should be connected to an adequate
mechanical exhaust system.
THE INSTALLATION INSTRUCTIONS CONTAINED HEREIN ARE FOR THE USE OF
QUALIFIED INSTALLAION AND SERVICE PERSONNEL ONLY. INSTALLATION OR
SERVICE BY OTHER THAN QUALIFIED PERSONNEL MAY RESULT IN DAMAGE TO THE
BR/INJURY TO THE OPERATOR.
READ CAREFULLY AND FOLLOW THESE INSTRUCTIONS
THE OVEN MUST BE INSTALLED IN ACCORDANCE WITH THE LOCAL CODES, OR
IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE, AN-
SI Z223.1-1988, INCLUDING:
1. The appliance and its individual shutoff valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test
pressures in excess of 1/2 psig. (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure testing of the gas supply
piping system at test pressure equal to or less than 1/2 psig. (3.45 kPa).
PROVISIONS MUST BE MADE FOR ADEQUATE AIR SUPPLY TO THE UNIT.