16
correspond to the HDBaseT outputs
1~4)
OFF[X][0].
Switch off all the outputs of a
splitter.
[X]: unit ID, varies from 00~15
OFF All
ON[X][Y1],[Y2],[Y3].
Switch on several outputs of the
splitter.
[X]: unit ID, varies from 00~15
[Y]: serial number of the output
port, varies from 1~5 (1 corresponds
to the HDMI® output, 2~5
correspond to the HDBaseT outputs
1~4)
On Y1, Y2, Y3
Y = 1~5
ON[X][0].
Switch on all the outputs of a
splitter.
[X]: unit ID, varies from 00~15
On All
Notes:
1.
In the above commands, the braces [ and ] are used to make the command easier to
read. They are not part of the actual command.
2.
Type in the complete command, including any embedded spaces and trailing
periods.
3.
When the unit ID is changed, reboot the unit before sending commands.
4.
Load the desired EDID file to the RS232 control software after sending the
command EDIDUpgrade[x][y]., then the screen will show "EDIDUpgrade success"
after the upgrade is completed.
5.
To control the third party devices via RS232 commands, type in the correct serial
number for the device's baud rate in the command. Following is a list of the baud
rates and corresponding serial numbers: