36" Frame to
Frame Width
*84" From
Floor to
Top Frame
35"
Case Width
*83-1/2"
at
Rear
25-3/8"
Case Depth
Depth Including Handles 26-7/8"
THE INSTALLATION SPACE
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 24”
The refrigerator will project forward, slightly beyond
adjacent cabinetry, depending on your installation.
Allow minimum 1/8” air gap between case back & wall.
Cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot exceed
the 24
”
installation depth shown. The top case trim
overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
NOTE: GFI (ground fault interrupter) is not recommended.
• Water line can enter the opening through the floor or
back wall. Route GE SmartConnect
™
kit or 1/4
”
O.D.
copper tubing between the cold water line and the water
connection location. The tubing should be long enough
to extend to the front of the refrigerator. Installation of
an easily accessible shut-off valve in the water line is
required.
DIMENSIONS AND CLEARANCES
* Shipping height. The
refrigerator can be
adjusted to fit into a
cutout that is 84-1/2
”
max. height. Note that
the top case trim at
the front is 1/2
”
higher
and will overlap upper
cabinetry or soffit. Use
leveling legs and wheels
for a maximum 1
”
height
adjustment.
Product Clearances
These refrigerators are equipped with a 3-position door
stop. The factory set 115° door swing can be adjusted to
90° if clearance to adjacent cabinets or walls is restricted.
6
6"
Wall View
Electrical
Area
84-1/2" max
Finished
Opening
75" From
Floor to Bottom
of Electrical Area
10"
24" Cutout Depth
35-1/2"
Finished Width
2-5/16"
5"
10"
10"
3-1/2"
3-1/2"
5"
3-1/2"
Water Supply
For Dual Installation
• If you are installing two refrigerators, side by side,
the installation space must be 71-1/2
”
wide.
NOTE: Additional cutout width may be required when side panels
are used. Add side panel thickness to the finished cutout to
calculate rough-in width.
• The water and electrical locations for each product must
be located as shown.
• A separate 115V, 60Hz., 15 or 20 amp power supply is
recommended for each product.
Allow 25
”
minimum clearance for
a full 130° door swing. Allow 15
”
for pan removal.
For a 90° door swing, allow 4
”
min. clearance to a wall. If the
90° door stop position is used, pan
access is maintained, but pan
removal is restricted.
See illustration on page 10 to
determine door swing interaction
with adjacent cabinets or
countertops.
Design Guide - Standard Installation
115° Door Swing
4”