![Mono Robin L Operating And Maintenance Manual Download Page 15](http://html1.mh-extra.com/html/mono/robin-l/robin-l_operating-and-maintenance-manual_1827437015.webp)
Robin L sealer RevA19 17-01-19
8.0 ADJUSTMENTS
It should be noted at this point that no two heat sealable materials will work the same at the
same machine settings.
WIRE TEMPERATURE CONTROLLER.
This component is used to control the level of impulse temperature. The desired setting is
controlled by altering the digital display by pressing the plus or minus buttons.
WIRE TEMPERATURE.
Controlled as set out above. For all gauges and types of film it is recommended that a low
setting is first tried, gradually increasing to find the lowest setting at which a satisfactory
clean cut-off is achieved. The number (on the controller) thus established should be noted
for future reference in relation to the particular type and gauge of film in use. On no account
should too high a setting be used as this will reduce the life of both sealing wire and sealing
pads and might give rise to unpleasant fumes.
Pulse light.
This comes on
when the
sealing wire is
powered