9b FITTING A TEMPLATE
•
Soft dough
Non-rotary templates can be fitted with nozzles. This requires screwing the
nozzles into the threaded holes provided.
Rotary templates can have plastic nozzles screwed into nozzle holders
(straight or offset).
OR
Metal nozzles secured in place by a separate nut.
1
Select template and nozzles required.
(Nozzles are not required for sheeting, staggered or stub templates)
2
Attach nozzles to template body:
3
Slide the template into the matching recess at the base of the pump assembly until
the stop is in position.
4
Tighten the nuts on the clamp strip (on underside of pump assembly) to secure
template.
NOTE.
If the nuts are not securely tightened, leakage of mix will occur,
affecting deposit weights.
TEMPLATE
BODY
NOZZLES
CLAMP STRIP NUTS
RECESS FOR TEMPLATE
DO NOT OPERATE MACHINE WITHOUT TEMPLATE FITTED
Omega
PLUS
Summary of Contents for OMEGA PLUS
Page 2: ......
Page 22: ...FG079 OMEGA TOUCH INCL WIRECUT 03 11 RAC 22 Omega PLUS ...
Page 53: ...FG079 OMEGA TOUCH WIRECUT 03 11 RAC 53 14 0 ELECTRICAL INFORMATION Omega PLUS ...
Page 54: ...FG079 OMEGA TOUCH WIRECUT 03 11 RAC 54 ...
Page 55: ...FG079 OMEGA TOUCH WIRECUT 03 11 RAC 55 ...
Page 56: ...FG079 OMEGA TOUCH WIRECUT 03 11 RAC 56 ...
Page 57: ...FG079 OMEGA TOUCH WIRECUT 03 11 RAC 57 ...
Page 58: ...FG079 OMEGA TOUCH WIRECUT 03 11 RAC 58 ...
Page 59: ...FG079 OMEGA TOUCH WIRECUT 03 11 RAC 59 ...
Page 60: ...FG079 OMEGA TOUCH WIRECUT 03 11 RAC 60 ...
Page 61: ...FG079 OMEGA TOUCH WIRECUT 03 11 RAC 61 ...
Page 62: ...FG079 OMEGA TOUCH WIRECUT 03 11 RAC 62 ...
Page 63: ...FG079 OMEGA TOUCH WIRECUT 03 11 RAC 63 ...
Page 64: ...FG079 OMEGA TOUCH WIRECUT 03 11 RAC 64 ...
Page 65: ...FG079 OMEGA TOUCH WIRECUT 03 11 RAC 65 ...