background image

 

 

CONTENTS 

 

SECTION 1: OPERATION OF THE CABINET ............................................... 3

 

SECTION 2: TESTING/MAINTENANCE ......................................................... 5

 

SECTION 3: SPECIFICATION OF THE CABINET ......................................... 9

 

SECTION 4: FACE VELOCITY PROFILE RESULTS ................................... 10

 

 

 
 
This manual is intended to provide information about the product.   
Monmouth Scientific Limited assumes no liability whatsoever for the accuracy of any information 
contained herein, as products can be subject to improvement changes at any time.

 

 

 

The contents may not be distributed, shared or commercially exploited in any form or by any 
means, redistributed or reproduced in entirety or in part in any form, for individual or third party 
use, photocopied or stored on any form of electronic retrieval system or linked to any other 
website, without the prior express written permission of Monmouth Scientific Limited.

 

 

 

For permission requests, please write to: - 
Monmouth Scientific Limited, 
Units 5 & 5 Kilnside, East Quay, Bridgwater, Somerset, TA6 4DB. 
Email

[email protected]

 

Tel: +44(0)1278 458090

 

 
 

Warning 
 
This cabinet must be used in compliance with these instructions and any 
repairs or maintenance carried out by qualified personnel. 
 
For parts or service information please contact Monmouth Scientific. 

 

Summary of Contents for Ductaire TITAN DT1000

Page 1: ...Operating Maintenance Manual www monmouthscientific co uk Ductaire TITAN Ducted Fume Cupboard DT1000 DT1200 DT1800 DT2000 ...

Page 2: ...y form or by any means redistributed or reproduced in entirety or in part in any form for individual or third party use photocopied or stored on any form of electronic retrieval system or linked to any other website without the prior express written permission of Monmouth Scientific Limited For permission requests please write to Monmouth Scientific Limited Units 5 5 Kilnside East Quay Bridgwater ...

Page 3: ...he fume cupboard chamber The sash will automatically stop at this height At all times make sure to close the sash fully thus providing maximum protection to the user If large equipment is to be loaded into the fume cupboard chamber the sash can be raised further by pushing the sash restrictor knob upwards once the sash is lowered the sash stop will automatically reset Note when raising the sash ab...

Page 4: ...arm panel user manual for further details Light The light switch is located on the left hand service panel at the top press to turn light on and off Double Sockets A switched double electrical socket is usually located on each service panel Services Depending on the fume cupboard configuration various service valves and taps may be fitted which may include cold water and gas etc Turn the valves an...

Page 5: ...h high Leakages Internal seals around panels and sinks etc Check glass sash for cracks chemical attack or any other damage Hygiene Services Illumination Noise Electrical isolation Routine maintenance Lubricate sash cables and pulleys Rocol 34235 Dry PTFE Spray Remove rear baffle and clean inner chamber with mild disinfectant Clean glass sash with standard glass cleaner Fan and Extract System Exami...

Page 6: ...d the exhaust take off section Removal of Front Service Panel To remove the front service panels remove socket head bolts and carefully pull service panel forward this will give you access to the service valves plumbing electrical sockets light switch and the alarm panel Please note Even if the fume cupboard junction box has been isolated the alarm panel can still be electrically connected via ano...

Page 7: ...r from date of delivery or installation with an extension of up to 5 years Subject to T C s Spare Parts Please contact our office for advice on replacement parts Phone 44 0 01278 458090 Option 2 Fax 44 0 01278 458091 Services monmouthscientific co uk ...

Page 8: ...8 Internal Wiring Schematic ...

Page 9: ...0mm W x 2400 H x 900 D Chamber 316g Stainless Steel Work base 316g Stainless Steel Manufacturer Connection Services NONE Drainage NONE Storage NONE Power 2 x D S S O Light LED Alarm Type AFA 1000E VAV alarm panel and controller c w VAV actuator and damper Extract System None ...

Page 10: ...400mm Fume Cupboard Type Ductaire Titan Fume Cupboard Ref XXXX Fume cupboard width 1000mm Sash width 700mm Sash height 500mm recommended 0 00 0 00 0 00 X X 0 00 0 00 0 00 X X 0 00 0 00 0 00 X X 100mm 100mm 100mm 100mm 500mm 700mm Anemometer Anemometer Serial Calibration Date Tested By Test Date Average Velocity Reading Notes ...

Page 11: ...t i s h D e s i g n Manufacture Monmouth Scientific Limited UK Headquarters Units 5 6 Kilnside East Quay Bridgwater Somerset TA6 4DB 44 0 1278 458090 www monmouthscientific co uk info monmouthscientific co uk ...