11
6.1 PROGRAMMING
6.1 GENERAL
Programming includes setting the valid
PIN, open duration time, invalid PIN
penalty time, and options for the door
propped, and forced door alarms and anti-
tailgating feature. These settings are only
accessible by first placing the Control
Panel into the Programming Mode and
then entering the programming sequences
listed in Table 6-1 on the keypad.
Programming sequences are entered on
the keypad in the form *FC*N*, where FC
is a 2-digit Function Code and N is a
numeric value.
Function
Sequence
Range of N
Default
PIN MANAGEMENT FUNCTIONS
Set Defaults
*00*
N/A
N/A
Delete PIN
*10*
N/A
N/A
Set PIN
*11*N*
000 to 999, 9999,
99999 or 999999
No valid
PIN
Penalty Time
*12*N*
5 to 60 (seconds)
5 seconds
Invalid PIN Alarm
*13*N*
0=Off, 1=On
Off
DOOR MANAGEMENT FUNCTIONS
Open Duration
*20*N*
01 to 60 (sec.)
5 seconds
Anti-Follow Through *21*N*
0=Off, 1=On
Off
Door Propped Alarm
Delay Time
*22*N*
1 to 255(sec.)=On,
0=Propped Alarm
Off
Off
Door Propped Alarm
Duration
*23*N*
15 to 255(sec),
0=Door Closed
Door
Closed
Forced Door Alarm
*24*N*
0=Off, 1=On
Off
Door Switch Sense
*25*N*
See Table
6.2 PROGRAMMING
INSTRUCTIONS
Enter the Programming Mode by pressing
the PROGRAM MODE button inside the
Control Panel. The red PROGRAM MODE
indicator LED in the Control Panel and the
green LED on the keypad will both begin to
flash, verifying that the Programming Mode
is active. To exit the Programming Mode
and return to the Normal Operation Mode
either press the PROGRAM MODE button
again or press the # key on the keypad.
The system will also revert to the Normal
Mode if no keys are pressed for 5 minutes.
6.2.1 Initial Settings
During a new installation or if you are
uncertain as to what settings have been
programmed previously, it is recommended
that the default values for all PIN and Door
Monitoring settings be set by entering *00*
on the keypad while in the Programming
Mode.
6.2.2 PIN Management
A new valid PIN code can be set only when
the system is in the Programming Mode.
To set a new valid PIN, enter *11*N*,
where N is any number containing 3, 4, 5,
or 6 digits.
To delete the current valid PIN enter *10*.
(This effectively disables the keypad since