background image

 

Crypto Lock 

CC-8521BN 

7/17

 

 

Access Control System 

 

INSTRUCTION MANUAL 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
           
 

 
 

MONITEQ, Inc.

 

Summary of Contents for Crypto Lock CC-8521BN

Page 1: ...1 Crypto Lock CC 8521BN 7 17 Access Control System INSTRUCTION MANUAL MONITEQ Inc...

Page 2: ...2...

Page 3: ...2 CONTROL PANEL 7 5 INSTALLATION 8 5 1 GENERAL 8 5 2 INSTALLATION PROCEDURE 8 5 3 POWER SUPPLY SETTINGS 9 6 1 PROGRAMMING 11 6 1 GENERAL 11 6 2 PROGRAMMING INSTRUCTIONS 11 6 2 1 INITIAL SETTINGS 11 6...

Page 4: ...noring all keypad entries for 3 to 60 seconds after an invalid digit is entered Further if five or more successive invalid PINs are entered the penalty time is set to 60 seconds until the valid PIN is...

Page 5: ...d Alarm Horn Output KEYPAD WITH STATUS LED REMOTE RELEASE BUTTON not supplied Door sensor Stand by Batteries Built in Horn and Release Buttom Ship s Central Alarm System Output Features 3 4 5 or 6 dig...

Page 6: ...3 to 60 seconds set to 60 seconds after five invalid PIN attempts Remote release input Dry contact closure Door monitoring functions Door propped open alarm forced door alarm anti tailgating Keypad D...

Page 7: ...rogramming codes Key Used as a delimiter for programming codes and parameters Key Used to terminate the programming mode Green LED indicator Programming mode Flashes continuously After a valid program...

Page 8: ...the secure side of door using the four mounting holes See diagram on page 18 Note All cables passing through holes made in enclosure must be protected from chafing Route all cables to avoid the batter...

Page 9: ...ent Greenleaf BRUTE can be damaged if powered for more than 15 seconds with unlimited current In the LIMit position up to 16A of current is available to initially open the lock but after the lock is o...

Page 10: ...TERY GROUND HORN T3 GROUND EXT RELEASE REQUEST TO EXIT Door Switch see table above DOOR SWITCH GROUND O R G W H T O R G 24 VDC 1 2 3 4 5 6 7 8 7 8 9 10 7 8 9 1 2 3 4 5 6 10 11 GROUND LOCK SWITCH GROUN...

Page 11: ...3 N 15 to 255 sec 0 Door Closed Door Closed Forced Door Alarm 24 N 0 Off 1 On Off Door Switch Sense 25 N See Table 6 2 PROGRAMMING INSTRUCTIONS Enter the Programming Mode by pressing the PROGRAM MODE...

Page 12: ...ion time enter 20 N where N is from 5 to 60 seconds Anti Tailgating The Anti Tailgating mode is provided to prevent the door from being re opened a second time during the Open Duration time period Thi...

Page 13: ...entering the valid PIN code on the Keypad will release the door The internal Release Button on the Control Panel can be used by an attendant to release the lock from a location on the secure side of...

Page 14: ...5 1 2 and 3 The relay controlling these contacts is activated continuously when a The door switch input T3 5 and T3 6 indicates that the door is ajar and b The Lock Switch Input T3 7 and T3 8 is open...

Page 15: ...15 CRYPTO LOCK Model CC 8421BN Keypad Mounting Template 3 5 8 4 5 8 3 4 D cable grommet Pilot holes Threaded inserts for 8 32 screw or threaded rod Keyhole for 8 screws 8 KEY PAD INSTALLATION TEMPLATE...

Page 16: ...16...

Page 17: ...17 9 CONTROL PANEL MOUNTING DIAGRAM 5 28 14 75 13 5 12 3 38 Mounting holes for 3 8 studs 4 places 1 4 Aluminum Mounting Bars...

Page 18: ...18...

Page 19: ...19...

Page 20: ...warranty is void in cases of abuse misuse mishandling modification or repair by unauthorized persons This warranty is given in lieu of all other warranties expressed or implied Moniteq is not liable...

Reviews: