Installation
WARNING: DO NOT CONNECT AC POWER CORD TO POWER SOURCE UNTIL
ALL SET UP IS COMPLETE!!!
Consult Figure 2 for installation.
1) Mount the keypad approximately 36 to 44 inches above the floor on the unsecured
side of the door. Use the keypad installation template to mark and drill holes. Through-
wall mounting can be accomplished using the #8 threaded rod, acorn nuts, hex nuts,
lock washer
s and 1 ½” washers. Alternatively, the keypad can be mounted using four
of the supplied #8 x 1 ½” pan head combo drive screws.
2) Mount the electric lock, strike or magnet according to manufacturer instructions.
3) Mount the control unit on the secure side of the door in an area convenient to the
door and
electrical outlet. Four #8 x 1 ½” pan head combo drive screws are provided.
4) If required, install the supplied cam lock in the knockout hole provided for that
purpose (on the enclosure door). Alternatively, if a padlock (not included) is to be used,
remove the two 3/8” nylon plugs from the padlock holes. The padlock’s shackle must
be first inserted through the hole on the side of the enclosure; the door can then be
closed so that the padlock hole on the door also passes over the shackle. If the door
does not need to be locked, the two supplied #6 x ½” screws can be used in the holes
on the door edge to hold it closed. Note: all cables passing through the knockout holes
in the enclosure must be protected fr
om chafing using the supplied 7/8” nylon
grommets. Route all cables to avoid the space in the bottom of the control unit that can
be occupied by batteries. Nylon tie wraps and self-adhesive nylon anchors are
supplied for this purpose.
5) Connect the keypad to the control unit by color. Fifteen feet of cable is supplied with
the keypad. The keypad can be located up to 200 feet from the control unit using
additional cable (14 conductors, #22 required).
6) Connect the electric lock, strike or magnet.
7) If used, connect the release button (not included) and external 12VDC annunciator
(not included, 2 conductors, #22 required). Note that an internal annunciator on the
Logic Board will sound when the keypad’s annunciator button is pressed.
8) Install and connect the optional batteries using the two supplied battery cables. Use
only 12V, 1.2 to 7AH rechargeable sealed lead acid batteries (Part # CC-BATT).
9) Connect the AC power cord to T4 according to the available voltage (115/230VAC).
10) Connect the transformer wires to T3 according to the available voltage
(115/230VAC). CAUTION: The control unit is factory wired for 115VAC operation.